MK_IMPULSE

12

Number of impulses per [MK_WEG]
(after the quadruplication!) in the order
of the axis number 0 ... 11

MK_WEG

12

Distance in [mm] or [degree] which
corresponds to the value of
[MK_IMPULSE] in the axis computer in
the order of the axis number 0 ... 11

MC keyword

No. of

values

Values

Meaning

MK_MODVMAX

12

Modal axis speed (manual traversing)
[m/min] or [U/min] in the order of the
axis number 0 ... 11

MK_VMAX

12

Max. axis speed [m/min] or [U/min] in
the order of the axis number 0 ... 11

MK_BESCHL

12

Acceleration ramp [m/s

2

] or [U/s

2

] in

order of the axis number 0 ... 11

MK_BREMS

12

Deceleration ramp [m/sec

2

] or [U/s

2

] in

the order of the axis number 0 ... 11

MK_T_BESCHL

12

Damping time constant for acceleration
and deceleration ramps [ms] in the order
of the axis number 0 ... 11

MC keyword

No. of

values

Values

Meaning

MK_VBAHNMAX

1

Max. material speed [m/min]

MK_BAHNBESCHL

1

Acceleration ramp [m/s

2

]

MK_BAHNBREMS

1

Deceleration ramp [m/s

2

]

MK_T_BAHNBESCHL

1

Dampening time constant for
deceleration and acceleration ramps [ms]

Setting of the axes

Axis−related limit values

Path−related limit values