Interface plc <˘> nc operating system – Lenze ETC Motion Control User Manual

Page 260

Advertising
background image

Interface PLC <˘> NC operating system

Definitions
Data block 1

5

5.1
5.1.2

l

260

EDSTCXN EN 2.0

Data word

Name

Direction

Type of signal

132.02

Block search active

NC

PLC

static

Value "1" of the signal indicates that the processing of an NC program is ac-
tive in the block search. The signal is pending until the target block of the
block search has been reached.

Data word

Name

Direction

Type of signal

132.03

Individual block is running

NC

PLC

static

Value "1" of the signal indicates that the processing of an individual block is
active, triggered by the individual block function (see ETC MMI) or by input
on the MMI (manual operation). The signal is pending until block termina-
tion ("NC program stop") or internal termination due to an error which can-
not be remedied.

Effect in the PLC: Evaluation for disable, synchronization, time measure-
ment.

Data word

Name

Direction

Type of signal

0132.04

Interrupt active

PLC

NC

static

Value "1" of the signal indicates that the NC is in the "Interrupt" state
(see also "Interrupt" signal).

Effect in the PLC: None.

Data word

Name

Direction

Type of signal

132.08

All axes stopped

NC

PLC

static

The signal always has value "1" when the axes have stopped or no command
for traversing the axis is currently active.

The signal "All axes stopped" is generated from the state signals of all axes.

Data word

Name

Direction

Type of signal

133.00−07

Optional hold

NC

PLC

static

This signal from the MMI activates a "Programmed hold" through M01.

Effect in the NC:

0 = optional hold inactive
1 = optional hold active

Advertising