Machine constants, List of machine constants – Lenze ETC Motion Control User Manual

Page 233

Advertising
background image

Machine constants

List of machine constants

4

4.16

l

233

EDSTCXN EN 2.0

10,

10,

10;

MK_SW_ENDS_MINUS

−10000,

/* software limit stop (+)−direction */

−10000,

/* [mm], relating to basic offset */

−10000,

−10000,

−10000,

−10000;

MK_SW_ENDS_PLUS

10000,

/* software limit stop (−)−direction */

10000,

/* [mm], relating to basic offset */

10000,

10000,

10000,

10000;

/* −−−−−−−−−−−−−−−−− */

/* controller setting */

/* −−−−−−−−−−−−−−−−− */

MK_DRIFTABGLEICH

0,

/* offset adjustment [mV] for analog */

0,

/* axis interfaces */

0,

0,

0,

0;

MK_REGLER_MODE

2,

/* 0 = control loop open */

2,

/* 1 = reserved */

2,

/* 2 = P controller */

2,

/* 3 = P controller with feed−forward */

2,

/* 4 = spindle */

2;

/* 5 = PID controller with feed−forward */

MK_KP

1,

/* KP of the P controller */

1,

/* (also for synchronous control) */

1,

1,

1,

1;

MK_TV

0,

/* rate time [s] for D component of */

0,

/* PID controller (also for synchronous control) */

0,

0,

0,

0;

MK_TN

0,

/* integral−action time [s] for integral action component of
*/

0,

/* PID controller (also for synchronous control) */

Advertising