Etc−mmi – Lenze ETC Motion Control User Manual

Page 335

Advertising
background image

ETC−MMI

Appendix

Configuration file (DELPHMMI.INI)

7

7.8

7.8.3

l

335

EDSTCXN EN 2.0

The configuration of the bar displays for Vist and Override can be changed
to display a different value from the DPR. Moreover, two different bar
displays below the axis positions can be configured in the Automatic
operating mode.

For this purpose, there is a new section [BarAnz] in the Delphmmi.ini. This
section contains up to four entries for the four bars.

Example:

[BARANZ]
ANZ1=0;800;10802;1;P30
ANZ2=0;800;10902;2;P31
ANZ3=0;3000;10920;3;4711;DOUBLE
Anz4=0;4000;10930;4;D10,WORD

The values of an entry have the following meaning:

1. Min value of the bar or the labelling (currently, the entries < 0 are not

supported)

2. Max value of the bar or the labelling (the Max value must be greater

than the Min value)

3. Text number of the descriptive text in the language text

4. Bar on which the value is to be displayed:

1= upper right (standard Vist)
2= lower right (standard Override)
3= upper left (standard invisible)
4= lower left (standard invisible)

5. The value to be displayed; there are three types of specifying a value:

PXX: Index on the field permanent display; the corresponding field must
be entered in the Delphmmi.ini in for the corresponding displays.
DXX: PLC DB2 display off 0 ... 63,
XXXX: Direct address in the DPR

6. If the information on the displayed value is specified via DB2 or via a

direct address, the value format must also be specified. The following
values are permitted:
BYTE
DOUBLE
INTEGER
LONG
SINGLE
WORD

For P fields the data type is always double.

BARANZ

Advertising