Interface plc <˘> nc operating system – Lenze ETC Motion Control User Manual

Page 265

Advertising
background image

Interface PLC <˘> NC operating system

Definitions

Data block 1

5

5.1

5.1.2

l

265

EDSTCXN EN 2.0

Data word

Name

Direction

Type of signal

160

H function

NC

PLC

Message

The data word contains the number of the H function in binary representa-
tion. For the description on the acceptance of an H function, refer to the "Pro-
gramming instructions".

Effect in the PLC: Execution of the function specified via the H function. Read
enable is activated after the function has been completed or at another sui-
table point in time.

Data word

Name

Direction

Type of signal

177.00−15

Home position approached

NC

PLC

static

The signal has the value "1" if a home position approach has been carried out
successfully and the value "0" after the control has been switched on and if
the home position is unknown.

Effect in the PLC: Checking the home position approach and disabling ma-
chine functions or traversing movements (feed enable) if the home position
is not approached.

Data word

Name

Direction

Type of signal

178.00−15

Limit switch + active

NC

PLC

static

The signal has the value "1" if the positive limit switch of an axis is active,
otherwise value "0".

Effect in the PLC: Disabling machine functions or traversing movements
(feed enable).

Data word

Name

Direction

Type of signal

179.00−15

Limit switch − active

NC

PLC

static

The signal has the value "1" if the negative limit switch of an axis is active,
otherwise value "0".

Effect in the PLC: Disabling machine functions or traversing movements
(feed enable).

Data word

Name

Direction

Type of signal

180.00−15

Reference switch active

NC

PLC

static

The signal has the value "1" if the reference switch of an axis is active, other-
wise value "0".

Effect in the PLC: If required, man. execution of homing via the PLC.