Interface plc <˘> nc operating system – Lenze ETC Motion Control User Manual

Page 266

Advertising
background image

Interface PLC <˘> NC operating system

Definitions
Data block 1

5

5.1
5.1.2

l

266

EDSTCXN EN 2.0

Data word

Name

Direction

Type of signal

182.00−15

Slave axis limit switch + active

NC

PLC

static

The signal has the value "1" if the positive limit switch of the slave axis of a
synchronous axis is active, otherwise the value is "0".

Effect in the PLC: Disabling machine functions or traversing movements
(feed enable).

Data word

Name

Direction

Type of signal

183.00−15

Slave axis limit switch − active

NC

PLC

static

The signal has the value "1" if the negative limit switch of the slave axis of
a synchronous axis is active, otherwise the value is "0".

Effect in the PLC: Disabling machine functions or traversing movements
(feed enable).

Data word

Name

Direction

Type of signal

184.00−15

Slave axis reference switch active

NC

PLC

static

The signal has the value "1" if the reference switch of the slave axis of a syn-
chronous axis is active, otherwise the value is "0".

Effect in the PLC: If required, manual execution of homing via the PLC.

Advertising