Interface PLC <˘> NC operating system

Extended interface for MMI functions

Data block 15

5

5.2

5.2.2

l

273

EDSTCXN EN 2.0

5.2.2

Data block 15

The data block 15 represents the "virtual keyboard" of the NC computer. This
block can only be written by the PLC if no ETC−MMI is connected to the con-
trol. Otherwise the contents of the PLC can only be read.

Data word

Name

Direction

DR010
DL010
DR011
DW028 − 033
DW036 − 039
DW040 − 043
DW044 − 047

Optional hold
Individual/following block
Hide block
Traverse keys axis 0 − 11
Override selector switch 1 − 4
Speed preselection for traverse keys
Increment preselection

HMI

NC

HMI

NC

HMI

NC

HMI

NC

HMI

NC

HMI

NC

HMI

NC

Data word

Name

Direction

Type of signal

010.00−07

Optional hold

HMI

NC

static

Activation of the execution of M01. This signal is not evaluated by the NC
core, the corresponding function must be implemented in the PLC, if requi-
red, by withdrawing the feed or read enable for M01.

Effect in the NC:

0 = optional hold inactive
1 = optional hold active

Data word

Name

Direction

Type of signal

010.08−15

Individual/following block

HMI

NC

static

Change over from following to individual block operation and vice versa.

Effect in the NC: Processing of a program either continuously (following
block) or block by block (individual block).

0 = following block
1 = individual block

Data word

Name

Direction

Type of signal

011.00−07

Hide block

HMI

NC

static

With this signal, the "Satz ausblenden" ("Hide block") function can be swit-
ched on or off.

Effect in the NC: Blocks with a preceding "/" are hidden, i.e. they are not ex-
ecuted:

0 = Hide block inactive
1 = Hide block active

Assignment