Interface plc <˘> nc operating system, Definitions data block 1 – Lenze ETC Motion Control User Manual

Page 246

Advertising
background image

Interface PLC <˘> NC operating system

Definitions
Data block 1

5

5.1
5.1.2

l

246

EDSTCXN EN 2.0

Direction

Name

Data word

033.00

db1_sps2nc_hfkt_quitt_bit

PLC

® NC

035.00

db1_sps2nc_extsync_enable_bit

PLC

® NC

035.08

db1_sps2nc_programmhalt_aktiv_bit

PLC

® NC

036.00 – 037.15
038.00 – 039.15

db1_sps2nc_qin_mask_aw
db1_sps2nc_qout_mask_aw

PLC

® NC

PLC

® NC

042.00 – 043.15
044.00 – 045.15

db1_sps2nc_qin_offset_ab
db1_sps2nc_qout_offset_ab

PLC

® NC

PLC

® NC

080.00 – 080.15
081.00 – 081.15
082.00 – 082.15
083.00 – 083.15

db1_sps2nc_spsoverride_allg_w
db1_sps2nc_spsoverride_spindel_w
db1_sps2nc_spsoverride_ozillation_w
db1_sps2nc_spsoverride_sps_w

PLC

® NC

PLC

® NC

PLC

® NC

PLC

® NC

084.00 – 091.15

db1_sps2nc_verfahr_ab

PLC

® NC

128.00
128.01

db1_nc2sps_betriebsbereit_1_bit
db1_nc2sps_betriebsbereit_2_bit

PLC

¬ NC

PLC

¬ NC

129.00 – 129.15

db1_nc2sps_referenzpunkt_w

PLC

¬ NC

130.00 – 131.15

db1_nc2sps_referenzfahrt_laeuft_w

PLC

¬ NC

131.00 – 131.15

db1_nc2sps_betriebsart_w

PLC

¬ NC

132.00
132.02
132.03
132.04

db1_nc2sps_nc_programm_laeuft_bit
db1_nc2sps_satzvorlauf_aktiv_bit
db1_nc2sps_einzelsatz_laeuft_bit
db1_nc2sps_unterbrechen_aktiv_bit

PLC

¬ NC

PLC

¬ NC

PLC

¬ NC

PLC

¬ NC

132.08

db1_nc2sps_alle_achsen_stehen_bit

PLC

¬ NC

133.00 – 133.07

db1_nc2sps_wahlweise_halt_b

PLC

¬ NC

133.08 – 133.15

db1_nc2sps_programmstartzaehler_b

PLC

¬ NC

134.00 – 134.15

db1_nc2sps_achse_faehrt_w

PLC

¬ NC

135.00 – 135.15

db1_nc2sps_modal_am_ziel_w

PLC

¬ NC

137.00 – 137.07

db1_nc2sps_programmstart_b

PLC

¬ NC

137.08 – 137.15

db1_nc2sps_einzel_folgesatz_bit

PLC

¬ NC

138.00 – 138.15
139.00 – 139.15

db1_nc2sps_canmodul_vorhanden_w
db1_nc2sps_can_status_w

PLC

¬ NC

PLC

¬ NC

142.00

db1_nc2sps_programmstop_b

PLC

¬ NC

144.00

db1_nc2sps_vorschub_halt_b

PLC

¬ NC

150.00
151.00 – 151.15

db1_nc2sps_mfkt_strobe_bit
db1_nc2sps_mfkt_w

PLC

¬ NC

PLC

¬ NC

159.00
160.00 – 160.15

db1_nc2sps_hfkt_strobe_bit
db1_nc2sps_hfkt_w

PLC

¬ NC

PLC

¬ NC

177.00 – 177.15

db1_nc2sps_refpunkt_angefahren_w

PLC

¬ NC

178.00 – 178.15
179.00 – 179.15
180.00 – 180.15
181.00 – 181.15

db1_nc2sps_endschalter_plus_w
db1_nc2sps_endschalter_minus_w
db1_nc2sps_referenznocken_w
db1_nc2sps_reserveeingang_w

PLC

¬ NC

PLC

¬ NC

PLC

¬ NC

PLC

¬ NC

182.00 – 182.15
183.00 – 183.15
184.00 – 184.15
185.00 – 185.15

db1_nc2sps_slave_endschalter_plus_w
db1_nc2sps_slave_endschalter_minus_w
db1_nc2sps_slave_referenznocken_w
db1_nc2sps_slave_reserveeingang_w

PLC

¬ NC

PLC

¬ NC

PLC

¬ NC

PLC

¬ NC

192.00 – 199.15

db1_nc2sps_copmodul_vorhanden_aw

PLC

¬ NC

200.00 – 200.15
201.00 – 201.15
202.00 – 202.15
203.00 – 203.15

db1_nc2sps_spsoverride_allg_w
db1_nc2sps_spsoverride_spindel_w
db1_nc2sps_spsoverride_ozillation_w
db1_nc2sps_spsoverride_sps_w

PLC

¬ NC

PLC

¬ NC

PLC

¬ NC

PLC

¬ NC

204.00 – 211.15

db1_nc2sps_verfahr_ab

PLC

¬ HMI

212.00 – 219.15

db1_nc2sps_mmi_tasten_aw

PLC

¬ HMI

All of the areas that are not listed explicitly are reserved.