Interface plc <˘> nc operating system – Lenze ETC Motion Control User Manual

Page 254

Advertising
background image

Interface PLC <˘> NC operating system

Definitions
Data block 1

5

5.1
5.1.2

l

254

EDSTCXN EN 2.0

Data word

Name

Direction

Type of signal

032.00

Acknowledgement for M function

PLC

NC

Acknowledgeme
nt

The signal is set to "0" when the PLC has detected the value "0" of the strobe
for M functions and accepted the data of the M functions transferred by the
NC. It is set to "1" when the strobe has accepted the value "1" again (

240).

Effect in the NC: If the signal has the value "1", new data can be transferred
to the PLC; in the case of value "0", the PLC has accepted the pending data.
In this case, the strobe is set from "0" to "1" for signaling that the acceptance
was successful. When the signal changes from "1" to "0", the NC starts to
process the next block provided that the "Read enable" has been activated.

Data word

Name

Direction

Type of signal

033.00

Acknowledgement for H function

PLC

NC

Acknowledgeme
nt

The signal is set to "0" when the PLC has detected value "0" of the strobe for
H functions and accepted the data of the H functions which has been trans-
ferred by the NC. It is set to "1" when the strobe has accepted value "1" again.

Effect in the NC: If the signal has the value "1", new data may be transmitted
to the PLC, in the case of value "0", the PLC has accepted the pending data.
In this case, the strobe is set from "0" to "1" by the NC (acceptance signal has
been detected). If the data acceptance takes longer (>10 sec.), the "Read ena-
ble" signal must be canceled prior to setting the acknowledgement signal.

When the signal switches from "1" to "0", the NC starts to process the next
block if "Einlesefreigabe" "Read enable" has been activated.

Data word

Name

Direction

Type of signal

035.00

Enable ext. synchronization signal

PLC

NC

Enable

Meaning: reserved

Effect in the NC: reserved

Data word

Name

Direction

Type of signal

035.08

Program stop active

PLC

NC

static

The PLC uses "1" to signal to the HMI that the process of a NC program has
been stopped.

Effect in the NC: none

Advertising