16 list of machine constants, List of machine constants, Machine constants – Lenze ETC Motion Control User Manual

Page 226

Advertising
background image

Machine constants

List of machine constants

4

4.16

l

226

EDSTCXN EN 2.0

4.16

List of machine constants

In the following, you can find the list of machine constants as it is loaded in
the control. The list is provided as an ASCII file and can be edited on a PC. The
structure of the list corresponds to the previous description. It is
recommended to enter the required values for all machine constants.

Do not change the key values listed. Only change or add the corresponding
numerical values.

The individual numerical values within a keyword end with a "," (comma).
The last numerical value must end with a ";" (semicolon).

During editing, make sure not to delete the comment characters ("/*", "*/")
accidentally.

/*==============================================================*/

/* Sample machine constants V1.74 for ETCxC */

/*−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−*/

/*

** PLEASE NOTE

** −−−−−−−−−−−−−−

**

** Sequence of axes:

** The internal order of axes is defined via MK_APPLACHSIDX.

** All axis−specific machine constants must be configured

** in this order.

**

** Machine configuration:

** The machine constant MK_DW224_255 at the end of this file

** contains important information for the PLC. For further information,

** refer to the comment next to the machine constant.

**

*/

/*==============================================================*/

/*−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−*/

/* 0. Test settings */

/*−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−*/

MK_TEST_OHNEMECHANIK

0;

/* Axis computer is in operation, but does not observe the
*/

/* Actual position counter */

MK_SPS_DUMMY

0;

/* 0 = with integrated PLC; 1 = without */