You can use the IP Catalog to generate an Altera transceiver reconfiguration controller.
• For Arria V GZ and Stratix V devices, select the Transceiver Reconfiguration Controller.

• For Stratix IV devices, select the

ALTGX_RECONFIG

transceiver reconfiguration block.

When you configure the Altera Transceiver Reconfiguration Controller, you must specify the number of

reconfiguration interfaces. The number of reconfiguration interfaces required for the 40GbE and 100GbE

IP cores depends on the IP core variation.

Table 2-4: Number of Reconfiguration Interfaces

Lists the number of reconfiguration interfaces you should specify for the Altera Transceiver Reconfiguration

Controller for your Arria V GZ or Stratix V 40-100GbE IP core that includes a PHY component.

PHY Configuration

RX Only

TX Only

Duplex

Standard 40GbE and

40GBASE-KR4

(4x10.3125 lanes)

4

8

8

100GbE (10x10.3125

lanes)

10

20

20

CAUI-4 (4x25.78125

lanes)

4x3

(9)

You can configure your reconfiguration controller with additional interfaces if your design connects with

multiple transceiver IP cores. You can leave other options at the default settings or modify them for your

preference.
You should connect the

reconfig_to_xcvr

and

reconfig_from_xcvr

ports of the 40-100GbE IP core to

the corresponding ports of the reconfiguration controller.
The CAUI–4 variations have four reconfiguration channels, numbered consecutively from

reconfig_to_xcvr0

and

reconfig_from_xcvr0

to

reconfig_to_xcvr3

and

reconfig_from_xcvr3

.

The CAUI–4 reconfiguration channels must be connected to the four reconfiguration controller

groupings. The reconfiguration controller groupings include

ch0_2_from_xcvr

,

ch3_5_from_xcvr

,

ch6_8_from_xcvr

, and

ch9_11_from_xcvr

.

You must also connect the

mgmt_clk_clk

and

mgmt_rst_reset

ports of the Altera Transceiver Reconfi‐

guration Controller. The

mgmt_clk_clk

port must have a clock setting in the range of 100–125MHz; this

setting can be shared with the 40-100GbE IP core

clk_status

port. The

mgmt_rst_reset

port must be

deasserted before, or deasserted simultaneously with, the 40-100GbE IP core

pma_arst_ST

port.

(9)

The CAUI-4 configuration requires 12 interfaces split into four groups of three; the interface grouping

should be set to 3, 3, 3, 3.

2-12

External Transceiver Reconfiguration Controller

UG-01088

2014.12.15

Altera Corporation

Getting Started