100GbE IP Core RX Client Interface Examples

Example on RX Client Interface Without Preamble Pass-Through
Figure 3-26: Typical Traffic on the RX Client Interface for 100GbE IP Core Without Adapters and with

Preamble Pass-Through Turned Off

/e100_tb/dut/dout_d

070707070707070...

363738393a3b3c3...5e5f606162636465...

020202020202010...8788898a8b8c8d8...afb0b1b2b3b4b5b6...

fb55555

070707070707070...

/e100_tb/dut/dout_c

000007ffff

ffffffff80

ffffffffff

000000003f

0000000000

0000000000

800

10

08

00

00

/e100_tb/dut/dout_first_data

0000800000

0000000400

0000000000

0000000000

/e100_tb/dut/dout_last_data

00

00

/e100_tb/dut/dout_runt_last_data

1f

1c

00

1f

1e

00

0f

/e100_tb/dut/dout_payload

/e100_tb/dut/dout_fcs_error

/e100_tb/dut/dout_fcs_valid

00

/e100_tb/dut/dout_dst_addr_match

/e100_tb/dut/dout_valid

/e100_tb/dut/clk_rxmac

1

2

3

4

5

6

7

8

In the figure,

dout_last_data

is asserted in the second cycle, indicating the end of a packet. The

dout_d

signal returns to 0 (5’h1c = 5’b11100). The

dout_c

and

dout_d

busses are set to 1b’1 and 8’h07,

respectively, to indicate idling. In the fourth cycle,

dout_first_data

is asserted and a short packet begins.

This packet terminates successfully in the final cycle. Note that the first packet has a CRC error

(

dout_fcs_error

= 1 and

fcs_valid

= 1).

The

dout_first_data

signal marks the first word of data. The first byte of data is always the most signifi‐

cant byte of the word. There are 5 legal starting positions for the 100GbE IP core and 2 legal starting

positions for the 40GbE IP core. The

dout_last_data

signal marks the last data byte before the FCS

(CRC). It can occur at any byte position.
The

dout_runt_last_data

signal indicates that the packet ending in this word is less than the minimum

legal length of 64 bytes from first data to the last FCS byte inclusive. Runt frames of eight or fewer bytes

cannot be legally represented in CGMII and trigger a decoding error rather than this flag.
The

dout_fcs_error

and

dout_fcs_valid

signals indicate the result of the CRC checking logic.

dout_fcs_valid

= 1 and

dout_fcs_error

= 1 indicate a corrupted frame. Note that the CRC checking

network works correctly on runt frames of 40–63 bytes. Runt frames of less than 40 bytes may be

incorrectly determined to have a proper CRC.

3-30

100GbE IP Core RX Client Interface Examples

UG-01088

2014.12.15

Altera Corporation

Functional Description

Send Feedback