To configure the file transfer type in batches:

1.

Click Service > BIMS > Resource Management > Batch Operate.

2.

On the Batch Operate page, click Configure File Transfer Type.

3.

On the Configure File Transfer Type page, click Add CPE.

4.

On the CPE List page, select the target CPEs, and then click OK.

5.

Specify the Transfer Type is HTTP or HTTPS, and then click Apply.

Setting an auto restore strategy

This function enables you to configure multiple CPEs in batches to automatically restore configuration or

software to the baseline version. For more information, see "

Deploying configurations and software

using the Deployment Guide

."

To auto set the restore strategy in batches:

1.

Click Service > BIMS > Resource Management > Batch Operate.

2.

On the Batch Operate page, click Set Auto Restore Strategy.

3.

On the Set Auto Restore Strategy page, click Add CPE.

4.

On the CPE List page, select the target CPEs, and then click OK.

5.

Select whether to enable the Auto Restore Configuration and Auto Restore Software functions, and
then click OK.

Configuring IP ping test

To configure the IP ping test in batches:

1.

Click Service > BIMS > Resource Management > Batch Operate.

2.

On the Batch Operate page, click IP Ping Test.

3.

On the IP Ping Test page, complete the following parameters:

{

Timeout—Specify the timeout period in seconds. If the response time is over the limitation, the
test result is failed.

{

IP Packets Size—Specify the IP packets size.

{

Number—Specify how many the BIMS sends for each ping round.

{

DSCP—Specify the DSCP value of the IP packet.

{

Host—Specify the source host address.

4.

Click Add CPE.

5.

On the CPE List page, select one or more target CPEs, and then click OK.
BIMS enables you to ping several different CPE devices from the host at the same time.

6.

Click Test to launch the test process.
The test results appear on the IP Ping Test Results page.

Configuring the data model

BIMS provides the data model as a mechanism for sending and receiving parameter information from