1.2 SPECIFICATIONS

1 INTRODUCTION

1

1.2SPECIFICATIONS

1.2.1 489 SPECIFICATIONS

POWER SUPPLY

Options:

LO / HI
(must be specified when ordering)

LO Range:

DC: 20 to 60 V DC
AC: 20 to 48 V AC at 48 to 62 Hz

HI Range:

DC: 90 to 300 V DC
AC: 70 to 265 V AC at 48 to 62 Hz

Power:

45 VA (max), 25 VA typical

Proper operation time without supply voltage: 30 ms

AC ANALOG INPUTS FREQUENCY TRACKING

Frequency Tracking:

Va for wye, Vab for open delta
6 V minimum, 10 Hz/sec.

OUTPUT AND NEUTRAL END CURRENT INPUTS

CT Primary:

10 to 50000 A

CT Secondary:

1 A or 5 A (must be specified with order)

Conversion Range:

0.02 to 20

× CT

Accuracy:

at

< 2 × CT: ±0.5% of 2 × CT

at

≥ 2 × CT: ±1% of 20 × CT

Burden:

Less than 0.2 VA at rated load

CT Withstand:

1 second at 80 times rated current
2 seconds at 40 times rated current
continuous at 3 times rated current

GROUND CURRENT INPUT

CT Primary:

10 to 10000 A (1 A / 5 A CTs)

CT Secondary:

1 A / 5 A or 50:0.025 (HGF CTs)

Conversion Range:

0.02 to 20

× CT for 1 A / 5 A CTs

0.0 to 100 A pri. for 50:0.025 CTs (HGF)

50:0.025 CT Accuracy: ± 0.1 A at

< 10 A

± 1.0 A at

≥ 10 to 100 A

1 A / 5 A CT Accuracy:

at

< 2 × CT: ±0.5% of 2 × CT

at

2

× CT: ±1% of 20 × CT

GROUND CT BURDEN

GROUND CT CURRENT WITHSTAND (

SECONDARY

)

PHASE VOLTAGE INPUTS

VT Ratio:

1.00 to 240.00:1 in steps of 0.01

VT Secondary:

200 V AC (full-scale)

Conversion Range:

0.02 to 1.00

× Full Scale

Accuracy:

±0.5% of Full Scale

Max. Continuous:

280 V AC

Burden:

> 500 KΩ

NEUTRAL VOLTAGE INPUT

VT Ratio:

1.00 to 240.00:1 in steps of 0.01

VT Secondary:

100 V AC (full-scale)

Conversion Range:

0.005 to 1.00

× Full Scale

Accuracy:

Fundamental:+/-0.5% of Full Scale
3rd Harmonic at >3V secondary: +/-5%
of reading
3rd Harmonic at < 3V secondary: +/-
0.15% of full scale

Max. Continuous:

280 V AC

DIGITAL INPUTS

Inputs:

9 opto-isolated inputs

External Switch:

dry contact

< 400 Ω, or open collector

NPN transistor from sensor
6 mA sinking from internal 4K pullup at
24 V DC with Vce

< 4 V DC

489 Sensor Supply:

24 V DC at 20 mA max.

RTD INPUTS

RTDs (3 wire type):

100

Ω Platinum (DIN.43760)

100

Ω Nickel, 120 Ω Nickel,

10

Ω Copper

RTD Sensing Current:

5 mA

Isolation:

36 Vpk
(isolated with analog inputs and outputs)

Range:

–50 to +250°C

Accuracy:

±2°C for Platinum and Nickel
±5°C for Copper

Lead Resistance:

25

Ω Max per lead

No Sensor:

>1 kΩ

Short/Low Alarm:

< –50°C

TRIP COIL SUPERVISION

Applicable Voltage:

20 to 300 V DC/AC

Trickle Current:

2 to 5 mA

ANALOG CURRENT INPUTS

Current Inputs:

0 to 1 mA, 0 to 20 mA, 4 to 20mA
(setpoint)

Input Impedance:

226

Ω ±10%

Conversion Range:

0 to 2 mA

Accuracy:

±1% of full scale

Type:

Passive

Analog Input Supply:

+24 V DC at 100 mA max.

Sampling Interval:

50 ms

COMMUNICATIONS PORTS

RS232 Port:

1, Front Panel, non-isolated

RS485 Ports:

2, Isolated together at 36 Vpk

GROUND

CT

INPUT

BURDEN

VA

Ω

1 A / 5 A

1 A

0.024

0.024

5 A

0.605

0.024

20 A

9.809

0.024

50:0.025

HGF

0.025 A

0.057

90.7

0.1 A

0.634

90.7

0.5 A

18.9

75.6

GROUND CT

WITHSTAND TIME

1 SEC.

2 SEC.

CONTINUOUS

1 A / 5 A

80

× CT

40

× CT

3

× CT

50:0.025 HGF

N/A

N/A

150 mA