Table 6–3: DNP IMPLEMENTATION TABLE

OBJECT

DESCRIPTION

REQUEST

RESPONSE

OBJ

VAR

FUNC.

CODES

QUAL.

CODES

(HEX)

FUNC.

CODES

QUAL.

CODES

(HEX)

1

0

Binary Input - All Variations

1

06

1

1

Binary Input

1

00, 01, 06

129

00, 01

1

2

Binary Input With Status

1

00, 01, 06

129

00, 01

2

0

Binary Input Change - All Variations

1

06, 07, 08

2

1

Binary Input Change Without Time

1

06, 07, 08

129

17, 28

2

2

Binary Input Change With Time

1

06, 07, 08

129

17, 28

10

0

Binary Output - All Variations

1

06

10

2

Binary Output Status

1

00, 01, 06

129

00, 01

12

1

Control Relay Output Block

5, 6

17, 28

129

17, 28

20

0

Binary Counter - All Variations

1,7,8,9,10

06

129

00, 01

20

5

32-Bit Binary Counter without Flag

1,7,8,9,10

06

129

00, 01

20

6

16-Bit Binary Counter without Flag

1,7,8,9,10

06

129

00, 01

21

0

Frozen Counter - All Variations

1

06

129

00, 01

21

9

32-Bit Frozen Counter without Flag

1

06

129

00, 01

21

10

16-Bit Frozen Counter without Flag

1

06

129

00, 01

30

0

Analog Input - All Variations

1

06

30

1

32-Bit Analog Input With Flag

1

00, 01, 06

129

00, 01

30

2

16-Bit Analog Input With Flag

1

00, 01, 06

129

00, 01

30

3

32-Bit Analog Input Without Flag

1

00, 01, 06

129

00, 01

30

4

16-Bit Analog Input Without Flag

1

00, 01, 06

129

00, 01

32

0

Analog Input Change - All Variations

1

06, 07, 08

32

1

32-Bit Analog Input Change Without Time

1

06, 07, 08

129

17, 28

32

2

16-Bit Analog Input Change Without Time

1

06, 07, 08

129

17, 28

32

3

32-Bit Analog Input Change With Time

1

06, 07, 08

129

17, 28

32

4

16-Bit Analog Input Change With Time

1

06, 07, 08

129

17, 28

50

1

Time and Date

1, 2

07 (Note 1)

129

07

60

1

Class 0 Data (Note 2)

1

06

129

60

2

Class 1 Data (Note 3)

1

06, 07, 08

129

60

3

Class 2 Data (Note 3)

1

06, 07, 08

129

60

4

Class 3 Data (Note 3)

1

06, 07, 08

129

80

1

Internal Indications

2

00 (Note 4)

129

No object (cold restart command)

13

No object (warm restart command)

14

No object (delay measurement command) (Note 5)

23

For Notes, see the IMPLEMENTATION TABLE NOTES on the following page.