2 secondary current injection test setup, Secondary current injection test setup -2 – GE 489 User Manual

Page 214

Advertising
background image

7-2

489 Generator Management Relay

GE Multilin

7.1 TEST SETUP

7 TESTING

7

7.1.2 SECONDARY CURRENT INJECTION TEST SETUP

Figure 7–1: SECONDARY CURRENT INJECTION TESTING

A2

A5

A7

A10

A12

A15

D2

D7

D12

D10

D15

D16

D20

V

A

V

G

G

G

G

G

R

R

R

R

G

R

A

A

A

D18

D22

C2

D17

D21

C1

D19

D23

C3

D24

C4

D25

RS485

RS485

B2

A16

A23

D26

B3

A21

A17

A24

A19

A26

D27

COMPUTER

COMM.

RS485

AUXILIARY

RS485

ANALOG OUTPUTS

ANALOG INPUTS

ANALOG I/O

B4

A22

A18

A25

A20

A27

C

O

M

C

O

M

S

H

IE

L

D

2

+

2

+

C

O

M

+

2

4

V

D

C

1

+

1

+

3

+

3

+

4

+

4

+

-

C

O

M

D5

A1

A4

A6

A9

A11

A14

D1

D6

D11

D9

D14

D4

B1

500 Ohms

500 Ohms

500 Ohms

500 Ohms

RTD

SIMULATION

RESISTORS

OR RESISTANCE

DECADE BOX

500 Ohms

500 Ohms

500 Ohms

500 Ohms

500 Ohms

500 Ohms

500 Ohms

500 Ohms

A3

A8

A13

D3

D8

D13

COMPENSATION

COMPENSATION

COMPENSATION

COMPENSATION

COMPENSATION

COMPENSATION

HOT

COMPENSATION

COMPENSATION

COMPENSATION

COMPENSATION

COMPENSATION

COMPENSATION

HOT

HOT

HOT

HOT

HOT

HOT

HOT

HOT

HOT

HOT

ASSIGNABLE INPUT 1

ASSIGNABLE INPUT 2

ASSIGNABLE INPUT 3

ASSIGNABLE INPUT 4

ASSIGNABLE INPUT 5

ASSIGNABLE INPUT 6

ASSIGNABLE INPUT 7

COMMON

SWITCH +24Vdc

ACCESS

D

IG

IT

A

L

IN
PU

T

S

BREAKER

STATUS

HOT

RTD SHIELD

RTD RETURN

RTD RETURN

RTD RETURN

RTD RETURN

RTD RETURN

RTD RETURN

RTD #1

RTD #2

RTD #3

RTD #4

RTD #5

RTD #6

RTD #7

RTD #9

RTD #11

RTD #10

RTD #12

RTD #8

CONTROL

POWER

IRIG - B

SAFETY GROUND

TIMER

STOP

TRIGGER

SWITCH

+24VAC

SWITCH

COMMON

START

TRIGGER

START

TRIP COIL

SUPERVISION

R1 TRIP

R3 AUXILIARY

R5 ALARM

R2 AUXILIARY

R4 AUXILIARY

R6 SERVICE

SECONDARY INJECTION

TEST SETUP

FILTER GROUND

H12

G12

E12

E11

E2

E5

E8

F2

F5

F8

H11

G11

F12

F11

F1

F4

F7

E3

E6

E9

E1

E4

E7

F3

F6

F9

g

E10

V

N

E

UT

R

A

L

1

A

H

G

F

1

A

/5

A

1

A

/5

A

1

A

/5

A

1

A

/5

A

1

A

/5

A

1

A

/5

A

C

O

M

C

O

M

C

O

M

C

O

M

C

O

M

PHASE a PHASE b PHASE c

PHASE A PHASE B PHASE C

C

O

M

C

O

M

C

O

M

V

a

V

b

V

c

o

m

V

c

H10 G3

G6

H4

H7

H1

F10

A

B

C

N

A

B

C

N

V V V V

I

I

I

I

3 PHASE VARIABLE AC TEST SET

GROUND INPUTS

NEUTRAL END CT's

OUTPUT CT's

PHASE

VOLTAGE INPUTS

G9

H3

H6

G5

G8

H2

808818A3.CDR

G10

H9

G4

G7

G2

H5

H8

G1

AUTOMATIC CT

SHORTING

BAR

VC

VA

VB

GE Multilin