1-80 System Software Upgrade Procedures

Installing PsAxCtl Document EXE

a. Click OK to acknowledge the change directory warning.

b. At the PsAxCtl Document EXE Setup Welcome window, click

OK.

c. Verify that the destination directory is:

C:\Honeywell\TPS50\System\Bin.

d. Click the large install button (PC icon).

e. At the Setup Complete window, click OK.

Installing CCL Deployment

a. At the Welcome window, click Next.

b. At the CCL Deployment Installation Complete window, click

Finish.

11. At the Engineering Tools Setup Complete window, click the No, I

will restart my computer later option and click Finish.

12. At the Choose ERDB File Location window, click Cancel.

13. At the Exit Setup window, click Exit Setup.

Installing ProcessLogix Client Software

14. At the Welcome to ProcessLogix Server Setup window, click Next.

15. At the Choose Setup Type window, click the ProcessLogix Server

Client setup button (laptop computer icon).

TIP

You do not install ERDB on the client. Cancel out of
migrate and continue.

TIP

You must install Microsoft Excel prior to installing
Microsoft Excel Data Exchange.