Reliability testing, F reliability testing – NewTek TriCaster 8000 User Manual

Page 519

Advertising
background image

Page | 503

F RELIABILITY TESTING

We know our products play vital roles in the productions of our customers.
Durability and consistent, robust performance are much more than just adjectives
for your business and ours.

For this reason, all NewTek products undergo rigorous reliability testing to ensure
they meet our exacting test standards. For TriCaster 8000, 860 and 460, the
following standards are applicable:

Test Parameter

Evaluation Standard

Temperature

Mil-Std-810F Part 2, Sections 501 & 502

Ambient Operating

0°C and +40°C

Ambient Non-Operating

-10°C and +55°C

Humidity

Mil-STD 810, IEC 60068-2-38

Ambient Operating

20% to 90%

Ambient Non-Operating

20% to 95%

Vibration

ASTM D3580-95; Mil-STD 810

Sinusoidal

Exceeds ASTM D3580-95 Paragraph 10.4: 3 Hz to 500 Hz

Random

Mil-Std 810F Part 2.2.2, 60 minutes each axis,
Section 514.5 C-VII

Electrostatic Discharge

IEC 61000-4-2

Air Discharge

8K Volts

Contact

4K Volts

Advertising
This manual is related to the following products: