Figure 56, When connecting the, Yea_common – Yaskawa CIMR-LU Drives User Manual
Page 115: 4 start-up programming & operation

4 Start-Up Programming & Operation
YASKAWA ELECTRIC TOEP C710616 38F YASKAWA AC Drive L1000A Quick Start Guide
115
S
tart-U
p
Prog
rammin
g
&
Op
er
at
io
n
4
• Voltage Lower Than 190 to 340 Vdc for 200 V Class Drives, 380 to 680 Vdc for 400 V Class Drives, and 500 to 850
Vdc for 600 V Class Drives
Figure 49
Figure 56 Voltage Lower Than 190 to 340 Vdc for 200 V Class Drives, 380 to 680 Vdc for 400 V Class Drives,
and 500 to 850 Vdc for 600 V Class Drives
+
Current
sensor
R/L1
S/L2
T/L3
+1
+3
−
U/T1
V/T2
W/T3
Relay
Power
supply
board
Control
board
OPE
CN19
(A)
(C)
(B)
Battery for control circuit
200 V Class: 250 to 340 Vdc
400 V Class: 500 to 680 Vdc
600 V Class: 720 to 850 Vdc
DC bus
power supply
H1-
= 55
(Rescue Operation)
L1
L2
L3
DC bus power supply
200 V Class: 190 to 340 Vdc
400 V Class: 380 to 680 Vdc
600 V Class: 500 to 850 Vdc
L1000A
S
3
to S
12
SC
Magnetic Contactor Sequence
Magnetic Contactor B
Magnetic Contactor A
Magnetic Contactor C
H1-
= 55
(Rescue Operation)
After the DC bus voltage falls lower
than the battery voltage
0.5 s
YEA_common