Figure 56, When connecting the, Yea_common – Yaskawa CIMR-LU Drives User Manual

Page 115: 4 start-up programming & operation

Advertising
background image

4 Start-Up Programming & Operation

YASKAWA ELECTRIC TOEP C710616 38F YASKAWA AC Drive L1000A Quick Start Guide

115

S

tart-U

p

Prog

rammin

g

&

Op

er

at

io

n

4

• Voltage Lower Than 190 to 340 Vdc for 200 V Class Drives, 380 to 680 Vdc for 400 V Class Drives, and 500 to 850

Vdc for 600 V Class Drives

Figure 49

Figure 56 Voltage Lower Than 190 to 340 Vdc for 200 V Class Drives, 380 to 680 Vdc for 400 V Class Drives,

and 500 to 850 Vdc for 600 V Class Drives

+

Current

sensor

R/L1
S/L2
T/L3

+1

+3

U/T1
V/T2
W/T3

Relay

Power
supply

board

Control

board

OPE

CN19

(A)

(C)

(B)

Battery for control circuit
200 V Class: 250 to 340 Vdc
400 V Class: 500 to 680 Vdc
600 V Class: 720 to 850 Vdc

DC bus
power supply

H1-

= 55

(Rescue Operation)

L1
L2
L3

DC bus power supply

200 V Class: 190 to 340 Vdc
400 V Class: 380 to 680 Vdc
600 V Class: 500 to 850 Vdc

L1000A

S

3

to S

12

SC

Magnetic Contactor Sequence

Magnetic Contactor B

Magnetic Contactor A

Magnetic Contactor C

H1-

= 55

(Rescue Operation)

After the DC bus voltage falls lower
than the battery voltage

0.5 s

YEA_common