7 Option Card Installation

YASKAWA ELECTRIC TOEP C710616 38F YASKAWA AC Drive L1000A Quick Start Guide

157

Op

tion

Ca

rd

In

st

al

lat

io

n

7

Crimp Terminals

Yaskawa recommends using CRIMPFOX 6 by Phoenix Contact or equivalent crimp terminals with the specifications
listed in

Table 54

for wiring to ensure proper connections.

Note: Properly trim wire ends so loose wire ends do not extend from the crimp terminals.

Table 54 Crimp Terminal Sizes

6.

Route the option wiring.
Depending on the drive model, some drives may require routing the wiring through the side of the front cover to
the outside. For drive models CIMR-LU2A0008 through 2A0033, 4A0005 through 4A0018, and 5A0003 through
5A0010, cut out the perforated openings on the left side of the drive front cover as shown in

Figure 97

-A and

leave no sharp edges to damage wiring.
Route the wiring inside the enclosure as shown in

Figure 97

-B for drive models CIMR-LU2A0047 through

2A0415, 4A0024 through 4A0605, and 5A0013 through 5A0200 that do not require routing through the front
cover.

Figure 88

Figure 97 Wire Routing Examples

Wire Gauge

mm

2

Phoenix Contact Model

L

mm (in)

d1

mm (in)

d2

mm (in)

0.25 (24 AWG)

AI 0.25 - 6YE

10.5 (13/32)

0.8 (1/32)

2 (5/64)

0.34 (22 AWG)

AI 0.34 - 6TQ

10.5 (13/32)

0.8 (1/32)

2 (5/64)

0.5 (20 AWG)

AI 0.5 - 6WH

14 (9/16)

1.1 (3/64)

2.5 (3/32)

A – Route wires through the openings

provided on the left side of the
front cover.

<1>

(CIMR-LU2A0008 through 2A0033,
4A0005 through 4A0018, and
5A0003 through 5A0010)

<1> The drive will not meet NEMA Type 1 requirements if wiring is exposed outside the enclosure.

B – Use the open space provided

inside the drive to route option
wiring.
(CIMR-LU2A0047 through 2A0415,
4A0024 through 4A0605, and
5A0013 through 5A0200)

d1

d2

6 mm

(0.24 in.)

L

B

A