Yaskawa CIMR-LU Drives User Manual

Page 183

Advertising
background image

B Parameter Table

YASKAWA ELECTRIC TOEP C710616 38F YASKAWA AC Drive L1000A Quick Start Guide

183

Par

ame

te

r Ta

ble

B

1A

Accel/decel Ramp Selection 2

Used in conjunction with an input terminal set for “Accel/decel ramp selection 1” (H1-

= 7), and

allows the drive to switch between accel/decel ramp 3 and 4.

20 to 2F

External Fault

20: N.O., Always detected, ramp to stop
21: N.C., Always detected, ramp to stop
22: N.O., During run, ramp to stop
23: N.C., During run, ramp to stop
24: N.O., Always detected, coast to stop
25: N.C., Always detected, coast to stop
26: N.O., During run, coast to stop
27: N.C., During run, coast to stop
28: N.O., Always detected, Fast Stop
29: N.C., Always detected, Fast Stop
2A: N.O., During run, Fast Stop
2B: N.C., During run, Fast Stop
2C: N.O., Always detected, alarm only (continue running)
2D: N.C., Always detected, alarm only (continue running)
2E: N.O., During run, alarm only (continue running)
2F: N.C., During run, alarm only (continue running)

50

Nominal Speed

Closed: Activates the nominal speed (d1-19).

51

Intermediate Speed

Closed: Activates the Intermediate Speed (d1-20).

52

Releveling Speed

Closed: Activates the Releveling Speed (d1-23).

53

Leveling Speed

Closed: Activates the Leveling Speed (d1-26).

54

Inspection Operation

Closed: Activates Inspection operation using the speed set in d1-24.

55

Rescue Operation

Closed: Activates rescue operation.

56

Motor Contactor Feedback

Open: Motor contactor open
Closed: Motor contactor closed (N.O.)

57

High Speed Limit (Up)

Closed: Uses the leveling speed as the maximum speed when going up.

58

High Speed Limit (Down)

Closed: Uses the leveling speed as the maximum speed when going down.

5A

<44>

Motor Contactor Feedback 2

Open: Motor contactor closed (N.C.)
Closed: Motor contactor open

5B

<44>

Brake Feedback 2

Open: Brake open (N.C.)
Closed: Brake closed

5C

Floor Sensor

Closed: Initiate Direct Landing (S5-10 = 1)

67

Communications Test Mode

Tests the MEMOBUS/Modbus RS-485/422 interface. Displays “PASS” if the test completes
successfully.

79

Brake Feedback

Open: Brake closed
Closed: Brake open (N.O.)

<44> Available in drive software versions PRG: 7017 or later.

H1 Multi-Function Digital Input Settings

H1-

Setting

Function

Description

TOEP_C710616_38F_5_0.book 183 ページ 2013年12月4日 水曜日 午前9時56分

Advertising