5 Troubleshooting

132

YASKAWA ELECTRIC TOEP C710616 38F YASKAWA AC Drive L1000A Quick Start Guide

oFA00

Option Card Connection Error at Option Connector CN5-A, Option Card Fault at Option Connector
CN5-A
Option compatibility error

oFA01

Option Card Fault at Option Connector CN5-A
Option not properly connected

,

oFA05, oFA06

Option card error occurred at option port CN5-A

,

oFA10, oFA11

to

oFA12 to oFA17

to

oFA30 to oFA43

oFb00

Option Card Fault at Option Port CN5-B
Option compatibility error

oFb01

Option Card Fault at Option Port CN5-B
Option not properly connected

oFb02

Option Card Fault at Option Port CN5-B
Same type of option card already connected

to

oFb03 to oFb11

Option card error occurred at Option Port CN5-B

to

oFb12 to oFb17

oFC00

Option Card Connection Error at Option Port CN5-C
Option compatibility error

oFC01

Option Card Fault at Option Port CN5-C
Option not properly connected

oFC02

Option Card Fault at Option Port CN5-C
A maximum of two PG option boards can be used simultaneously. Remove the PG option board
installed into option port CN5-A.

to

oFC03 to oFC11

Option card error occurred at option port CN5-C

to

oFC12 to oFC17

oFC50

Encoder Option AD Conversion Error
Error with the A/D conversion level (VCC level), or A/D conversion timed out.

oFC51

Encoder Option Analog Circuit Error
Incorrect signal level (+2.5 V signal)

oFC52

Encoder Communication Timeout
Signal encoder timed out waiting to receive data

oFC53

Encoder Communication Data Error
Serial encoder CRC checksum error

oFC54

Encoder Error
Alarm reading EnDat absolute position data from encoder
(OR flag from EnDat error for overvoltage, undervoltage, etc.)

oH

Heatsink Overheat
The temperature of the heatsink exceeded the overheat pre-alarm level set to L8-02. Default value
for L8-02 is determined by drive capacity (o2-04).

oH1

Heatsink Overheat
The temperature of the heatsink exceeded the drive overheat level. The overheat level is determined
by drive capacity (o2-04).

oH3

Motor Overheat Alarm (PTC thermistor input)

• The motor overheat signal to analog input terminal A1 or A2 exceeded the alarm detection level.
• Detection requires multi-function analog input H3-02 or H3-10 be set to “E”.

oH4

Motor Overheat Fault (PTC thermistor input)

• The motor overheat signal to analog input terminal A1 or A2 exceeded the fault detection level.
• Detection requires that multi-function analog input H3-02 or H3-10 = “E”.