4 start-up programming & operation, Enter data from the motor nameplate – Yaskawa CIMR-LU Drives User Manual

Page 74

Advertising
background image

4 Start-Up Programming & Operation

74

YASKAWA ELECTRIC TOEP C710616 38F YASKAWA AC Drive L1000A Quick Start Guide

Enter Data from the Motor Nameplate

After selecting the type of Auto-Tuning, enter the data required from the motor nameplate.

Note: These instructions continue from Step 6 in “Selecting the Type of Auto-Tuning”.

6.

The display automatically returns to the display shown in Step 3.

Step

Display/Result

1.

Press

to access the motor output power parameter T1-02.

2.

Press

to view the default setting.

3.

Press

,

,

,

and

to enter the motor power nameplate

data in kW.

4.

Press

to save the setting.

5.

The display automatically returns to the display in Step 1.

6.

Repeat Steps 1 through 5 to set the following parameters:

• T1-03, Motor Rated Voltage
• T1-04, Motor Rated Current
• T1-05, Motor Base Frequency
• T1-06, Number of Motor Poles
• T1-07, Motor Base Speed

Step

Display/Result

- A.TUNE -

T1-

01

= 0

∗0∗

Standard Tuning

PRG

Tuning Mode

ESC

FWD

DATA

- A.TUNE -

T1-

02

= 3.70kW

(0.00 ~ 650.00)

PRG

Mtr Rated Power

ESC

FWD

DATA

“3.70kW”

- A.TUNE -

T1-02=

0

03.70kW

(0.00 ~ 650.00)

PRG

Mtr Rated Power

FWD

“3.70kW”

F1

left

F2

right

- A.TUNE -

T1-02= 004.0

0

kW

(0.00 ~ 650.00)

PRG

Mtr Rated Power

FWD

“3.70kW”

Entry Accepted

- A.TUNE -

T1-

02

= 4.00kW

(0.00 ~ 650.00)

PRG

Mtr Rated Power

ESC

FWD

DATA

“3.70kW”

- A.TUNE -

T1-

02

= 4.00kW

(0.00 ~ 650.00)

PRG

Mtr Rated Power

ESC

FWD

DATA

“3.70kW”

- A.TUNE -

T1-

07

= 1450RPM

(0 ~ 24000)

PRG

Rated Speed

ESC

FWD

DATA

“1450RPM”

TOEP_C710616_38F_5_0.book 74 ページ 2013年12月4日 水曜日 午前9時56分