Table 56 Power Ratings (Three-Phase 400 V Class)

Item

Specification

CIMR-LU4A

0005

0006

0007

0009

0015

0018

0024

0031

0039

0045

0060

Maximum Applicable Motor Capacity

(HP)

<1>

2

3

5

7.5

10

15

20

25

25-30

25-30

40

Input

Input Current (A)

<2>

3.6

5.1

8.3

12

16

23

31

38

44

43

58

Rated Voltage

Rated Frequency

Three-phase 380 to 480 Vac 50/60 Hz 510 to 680 Vdc

<3>

Allowable Voltage

Fluctuation

-15 to 10%

Allowable Frequency

Fluctuation

±5%

Input Power (kVA)

4.1

5.8

9.5

14

18

26

35

43

46.6 39.3 53.0

Output

Rated Output Capacity

(kVA)

<4>

3.5

<5>

4.1

<5>

6.3

<5>

9.8

<5>

12

<5>

17

<5>

22

<5>

27

<5>

30

<5>

34

<5>

48

<5>

Rated Output Current

(A)

3.5

<5>

4.1

<5>

6.3

<5>

9.8

<5>

12

<5>

17

<5>

22

<5>

27

<5>

39

<5>

45

<5>

60

<5>

Overload Tolerance

150% of rated output current for 60 s

Carrier Frequency

User adjustable between 2 and 15 kHz

Maximum Output

Voltage (V)

Three-phase 380 to 480 V (proportional to input voltage)

Maximum Output Speed

(Hz)

200 Hz (user-adjustable)

Item

<1> The motor capacity (HP) refers to a NEC rated 4-pole motor. The rated output current of the drive output amps should be equal to or greater

than the motor current. Select the appropriate capacity drive if operating the motor continuously above motor nameplate current.

<2> Assumes operation at the rated output current. Input current rating varies depending on the power supply transformer, input reactor, wiring

conditions, and power supply impedance.

<3> DC is not available for UL standards.

Specification

CIMR-LU4A

0075

0091

0112

0150

0180

0216

0260

0304

0370

0450

0605

Maximum Applicable Motor Capacity

(HP)

<1>

50-60

50-60

75

100

125-150

150

200

250

300

350

400-
450-

500

Input

Input Current (A)

<2>

71

86

105

142

170

207

248

300

346

410

584

Rated Voltage

Rated Frequency

Three-phase 380 to 480 Vac 50/60 Hz 510 to 680 Vdc

<3>

Allowable Voltage

Fluctuation

-15 to 10%

Allowable Frequency

Fluctuation

±5%

Input Power (kVA)

64.9 78.6 96.0 129.9 155

189

227

274

316

375

534

Output

Rated Output Capacity

(kVA)

<4>

57

<5>

69

<5>

85

<6>

114

<6>

137

<6>

165

<6>

198

<6>

232

<6>

282

<6>

343

<7>

461

<7>

Rated Output Current

(A)

75

<5>

91

<5>

112

<6>

150

<6>

180

<6>

216

<6>

260

<6>

304

<6>

370

<6>

450

<7>

605

<7>

Overload Tolerance

150% of rated output current for 60 s

Carrier Frequency

User adjustable

between

2 and 15 kHz

User adjustable between 2 and 10 kHz

User-adjustable

between

2 and 5 kHz

Maximum Output

Voltage (V)

Three-phase 380 to 480 V (proportional to input voltage)

Maximum Output Speed

(Hz)

200 Hz (user-adjustable)

400 Hz (user-adjustable)