Table 63 – Yaskawa CIMR-LU Drives User Manual

Page 226

Advertising
background image

C Standards Compliance

226

YASKAWA ELECTRIC TOEP C710616 38F YASKAWA AC Drive L1000A Quick Start Guide

Table 63 Wire Gauge and Torque Specifications (Three-Phase 400 V Class)

Model

CIMR-LU

Terminal

Recommended

Gauge

AWG, kcmil

Applicable Gauge

AWG, kcmil

Screw

Size

Tightening Torque

N m (lb.in.)

4A0005
4A0006
4A0007

R/L1, S/L2, T/L3

14

14 to 10

M4

1.2 to 1.5

(10.6 to 13.3)

U/T1, V/T2, W/T3

14

14 to 10

–, +1, +2

14 to 10

B1, B2

14 to 10

10

14 to 10

4A0009

R/L1, S/L2, T/L3

12

14 to 10

M4

1.2 to 1.5

(10.6 to 13.3)

U/T1, V/T2, W/T3

14

14 to 10

–, +1, +2

14 to 10

B1, B2

14 to 10

10

14 to 10

4A0015

R/L1, S/L2, T/L3

10

12 to 6

M4

2.1 to 2.3

(18.6 to 20.4)

U/T1, V/T2, W/T3

10

12 to 6

–, +1, +2

12 to 6

B1, B2

12 to 10

10

14 to 10

M5

2.0 to 2.5

(17.7 to 22.1)

4A0018

R/L1, S/L2, T/L3

10

10 to 6

M4

2.1 to 2.3

(18.6 to 20.4)

U/T1, V/T2, W/T3

10

10 to 6

–, +1, +2

12 to 6

B1, B2

12 to 10

10

12 to 10

M5

2.0 to 2.5

(17.7 to 22.1)

4A0024

R/L1, S/L2, T/L3

8

8 to 6

M5

3.6 to 4.0

(31.8 to 35.4)

U/T1, V/T2, W/T3

8

10 to 6

–, +1, +2

10 to 6

B1, B2

10 to 8

M5

2.7 to 3.0

(23.9 to 26.6)

8

10 to 8

M6

5.4 to 6.0

(47.8 to 53.1)

4A0031

R/L1, S/L2, T/L3

6

8 to 6

M5

3.6 to 4.0

(31.8 to 35.4)

U/T1, V/T2, W/T3

8

8 to 6

–, +1, +2

6

B1, B2

10 to 8

M5

2.7 to 3.0

(23.9 to 26.6)

6

10 to 6

M6

5.4 to 6.0

(47.8 to 53.1)

4A0039

R/L1, S/L2, T/L3

6

6 to 4

M6

5.4 to 6.0

(47.8 to 53.1)

U/T1, V/T2, W/T3

6

6 to 4

–, +1, +2

6 to 4

B1, B2

10 to 8

M5

2.7 to 3.0

(23.9 to 26.6)

6

8 to 6

M6

5.4 to 6.0

(47.8 to 53.1)

4A0045

<1>

R/L1, S/L2, T/L3

4

6 to 4

M8

9 to 11

(79.7 to 97.4)

U/T1, V/T2, W/T3

4

6 to 4

–, +1

6 to 1

B1, B2

8 to 4

6

8 to 6

TOEP_C710616_38F_5_0.book 226 ページ 2013年12月4日 水曜日 午前9時56分

Advertising