B Parameter Table

196

YASKAWA ELECTRIC TOEP C710616 38F YASKAWA AC Drive L1000A Quick Start Guide

o: Operator Related Parameters

The o parameters set up the digital operator displays.

o1: Digital Operator Display Selection

No.

Name

Description

Setting

o1-01

Drive Mode Unit Monitor
Selection

Switches the display after the power has been turned on. When using an LED
operator, pressing the up arrow key will display the following data: frequency
reference

→ rotational direction → output frequency → output current → output

voltage

→ U1-

.

(This is done by entering the 1

part of U1-

. Certain monitors are not available

in some control modes.)

Default: 106
(Monitor U1-06)
Min: 105
Max: 699

o1-02

User Monitor Selection
after Power Up

o1-02 selects the information that is displayed when the power is turned on.
1: Speed reference (U1-01)
2: Direction
3: Output speed (U1-02)
4: Output current (U1-03)
5: User-selected monitor (set by o1-01)

Default: 1
Min: 1
Max: 5

o1-03

Digital Operator Display
Unit Selection

Sets the units the drive should use to display the frequency reference and motor speed
monitors.
0: 0.01 Hz
1: 0.01% (100% = E1-04)
2: r/min (calculated using the number of motor poles setting in E2-04, E4-04, or E5-
04)
3: User-selected units (set by o1-10 and o1-11)
4: Elevator units 1 (speed in m/s, accel/decel rate and jerk in s)
5: Elevator units 2 (speed in m/s, accel/decel rate in m/s

2

, jerk in m/s

3

)

6: Elevator units 3 (speed in ft/min, accel/decel rate in ft/s

2

, jerk in ft/s

3

)

Default: 1
Min: 0
Max: 6

<21>

o1-04

V/f Pattern Setting Units

0: Hz
1: r/min

Default:

<5>

Min: 0
Max: 1

o1-05

LCD Contrast Control

Sets the brightness of the LCD operator (option).

Default: 3
Min: 0
Max: 5

o1-06

<44>

User Monitor Selection
Mode

0: 3 Monitor Sequential (Displays the next 2 sequential monitors)
1: 3 Monitor Selectable (o1-07 and o1-08 selected monitor is displayed)

Default: 0
Min: 0
Max: 1

o1-07

<44>

Second Line Monitor
Selection

Selects the monitor displayed on the second line.

Default: 102
Min: 101
Max: 699

o1-08

<44>

Third Line Monitor
Selection

Selects the monitor displayed on the third line.

Default: 103
Min: 101
Max: 699

o1-10

User-Set Display Units
Maximum Value

These settings define the display values when o1-03 is set to 3.
o1-10 sets the display value that is equal to the maximum output frequency.
o1-11 sets the position of the decimal position.

Default:

<20>

Min: 1
Max: 60000

o1-11

User-Set Display Units
Decimal Display

Default:

<20>

Min: 0
Max: 3

o1-12

Length Units

0: Millimeter unit
1: Inch unit

Default: 0
Min: 0
Max: 1

o1-20

Traction Sheave Diameter Sets the traction sheave diameter for display unit calculations.

Default:
400 mm

<38>

Min: 100 mm
Max:
2000 mm

<38>

TOEP_C710616_38F_5_0.book 196 ページ 2013年12月4日 水曜日 午前9時56分