4 Start-Up Programming & Operation

96

YASKAWA ELECTRIC TOEP C710616 38F YASKAWA AC Drive L1000A Quick Start Guide

S3-25: DC Injection Gain in Regenerative Operation

In OLV Control, S3-25 sets a gain level for DC Injection at stop (S1-03) for when the regenerative load reaches 100%. At
that time, the current applied during DC Injection at stop is determined as S1-03

× S3-25.

S3-26: DC Injection Gain in Motoring Operation

In OLV Control, S3-26 sets a gain level for DC Injection at stop (S1-03) when the motoring load reaches 100%. At that
time, the current applied during DC Injection at stop is determined as S1-03

× S3-26.

S3-27: Torque Compensation Value with Load Condition 1

Adjusts the analog signal from a load sensor for torque compensation. Refer to

Adjusting the Torque Compensation at

Start on page 88

for details.

S3-28: Torque Compensation Value with Load Condition 2

Adjusts the analog signal from a load sensor for torque compensation. Refer to

Adjusting the Torque Compensation at

Start on page 88

for details.

S3-29: Analog Input from Load Sensor with Load Condition 1

Adjusts the analog signal from a load sensor for torque compensation. Refer to

Adjusting the Torque Compensation at

Start on page 88

for details.

S3-30: Analog Input from Load Sensor with Load Condition 2

Adjusts the analog signal from a load sensor for torque compensation. Refer to

Adjusting the Torque Compensation at

Start on page 88

for details.

S3-34: Anti-Rollback Torque Bias 1

Sets an intermediary value for the torque bias used for Anti-Rollback when Position Lock at start is performed. This
setting rarely needs to be changed.

No.

Parameter Name

Setting Range

Default

S3-25

DC Injection Gain in Regenerative Operation

0 to 400%

100%

No.

Parameter Name

Setting Range

Default

S3-26

DC Injection Gain in Motoring Operation

0 to 400%

20%

No.

Parameter Name

Setting Range

Default

S3-27

Torque Compensation Value with Load Condition 1

-100.0 to 100.0%

-50.0%

No.

Parameter Name

Setting Range

Default

S3-28

Torque Compensation Value with Load Condition 2

-100.0 to 100.0%

50.0%

No.

Parameter Name

Setting Range

Default

S3-29

Analog Input from Load Sensor with Load Condition 1

-100.0 to 100.0%

0.0%

No.

Parameter Name

Setting Range

Default

S3-30

Analog Input from Load Sensor with Load Condition 2

-100.0 to 100.0%

100.0%

No.

Parameter Name

Setting Range

Default

S3-34

Anti-Rollback Torque Bias 1

0.0 to 100.0%

0.0%

TOEP_C710616_38F_5_0.book 96 ページ 2013年12月4日 水曜日 午前9時56分