B Parameter Table

YASKAWA ELECTRIC TOEP C710616 38F YASKAWA AC Drive L1000A Quick Start Guide

211

Par

ame

te

r Ta

ble

B

U4-17

Drive Overload
Calculations (OL2)

Displays the level of the drive overload detection (oL2). A value of 100% is equal
to the oL2 detection level.

10 V = 100%

0.1%

U4-18

Speed Reference
Selection Results

Displays the source for the speed reference as XY-nn.
X: indicates which reference is used:
1 = Reference 1 (b1-01)
Y-nn: indicates the reference source
0-01 = Digital operator
1-01 = Analog (terminal A1)
1-02 = Analog (terminal A2)
2-02 to 8 = Digital Inputs (d1-02 to 8)
3-01 = MEMOBUS/Modbus communications
4-01 = Communication option card

No signal output
available

U4-19

Speed Reference from
MEMOBUS/Modbus
Comm.

Displays the speed reference provided by MEMOBUS/Modbus (decimal).

No signal output
available

0.01%

<29>

U4-20

Speed Reference From
Option Card

Displays the speed reference input by an option card (decimal).

No signal output
available

0.01%

<29>

U4-21

Up/Down Command
Source Selection

Displays the source for the Up/Down command as XY-nn.
X: Indicates which Up/Down command source is used:
1 = Reference 1 (b1-02)
Y: Input power supply data
0 = Digital operator
1 = External terminals
3 = MEMOBUS/Modbus communications
4 = Communication option card
nn: Up/Down command limit status data
00: No limit status.
01: Up/Down command was left on when stopped in the PRG mode
02: Up/Down command was left on when switching from LOCAL to REMOTE
operation
03: Waiting for soft charge bypass contactor after power up (Uv or Uv1 flashes
after 10 s)
04: Waiting for "Up/Down Command Prohibited" time period to end
05: Fast Stop (multi-function input, operator)
07: During baseblock while coast to stop with timer
08: Speed reference is below minimal reference during baseblock
09: Waiting for Enter command

No signal output
available

U4-22

MEMOBUS/Modbus
Communications
Reference

Displays the drive control data set by MEMOBUS/Modbus communications
register no. 0001H as a four-digit hexadecimal number.

No signal output
available

U4-23

Communication Option
Card Reference

Displays drive control data set by an option card as a four-digit hexadecimal
number.

No signal output
available

U4-24

Number of Travels
(Lower 4 digit)

Displays the lower four digits for the number of trips the drive has made.

No signal output
available

1 time

U4-25

Number of Travels
(Higher 4 digit)

Displays the upper four digits for the number of trips the drive has made.

No signal output
available

1 time

U4-26

Max. Current during
Acceleration

Shows the maximum current that occurred during acceleration.

No signal output
available

0.1 A

U4-27

Max. Current during
Deceleration

Shows the maximum current that occurred during deceleration.

No signal output
available

0.1 A

U4-28

Max. Current during
Constant Speed

Shows the maximum current that occurred during ride at top speed.

No signal output
available

0.1 A

U4-29

Max. Current during
Leveling Speed

Shows the maximum current that occurred during ride at leveling speed.

No signal output
available

0.1 A

U4-30

Slip Compensation
Value

Shows the slip compensation value.

No signal output
available

0.01%

No.

Name

Description

Analog Output

Level

Unit

TOEP_C710616_38F_5_0.book 211 ページ 2013年12月4日 水曜日 午前9時56分