Operator Programming Errors

oPE Codes, Causes, and Possible Solutions

An Operator Programming Error (oPE) occurs when a contradictory parameter is set or an individual parameter is set to
an inappropriate value.

The drive will not operate until the parameter or parameters causing the problem are set correctly. An oPE, however, does
not trigger an alarm or fault output. If an oPE occurs, investigate the cause and refer to

Table 37

for the appropriate

action. When an oPE appears on the operator display, press the ENTER button to view U1-18 and see which parameter is
causing the oPE.

Table 37 oPE Codes, Causes, and Possible Solutions

Digital Operator Display

Error Name

oPE01

Drive Capacity Setting Fault
Drive capacity and the value set to o2-04 do not match.

oPE02

Parameter Range Setting Error
Use U1-18 to find parameters set outside the range.

oPE03

Multi-function Digital Input Selection Error
A contradictory setting is assigned to multi-function contact inputs H1-03 to H1-08.

oPE04

Terminal Board Mismatch Error

oPE05

Reference Source Selection Error

oPE06

Control Mode Selection Error
Correct the setting for the control method.

oPE07

Multi-function Analog Input Selection Error
A contradictory setting is assigned to multi-function analog inputs H3-02 and H3-10.

oPE08

Parameter Selection Error
A function has been set that cannot be used in the motor control method selected.

oPE10

V/f Pattern Setting Error
The following setting errors have occurred where:
E1-04 is greater than or equal to E1-06, E1-06 is greater than or equal to E1-07, E1-07 is greater than or
equal to E1-09, or E1-09 is greater than or equal to E1-11.

oPE16

Energy Savings Constants Error

oPE18

Parameter Setting Error, Online Tuning Parameter Setting Error

• The input from load cell with load condition 1 (S3-29) is set to the same value as load condition 2 (S3-

30).

• DWELL 2 related parameters are not set correctly.
• Parameters that control Online Tuning are not set correctly.

oPE20

PG-F3 Setting Error
The encoder signal frequency is too high.

oPE21

Elevator Parameter Setting Fault
Elevator parameters are not set correctly.