U2: Fault Trace

No.

Name

Description

Analog Output

Level

Unit

U2-01

<10> The display resolution depends on the rated output power of the drive. Models CIMR-LU2A0008 to 2A0033, 4A0005 to 4A0018, and 5A0003

to 5A0013 display values in 0.01 A units, while models CIMR-LU2A0047 to 2A0415, 4A0024 to 4A0605, and 5A0017 to 5A0200 display

values in 0.1 A units.

<29> Setting units are determined by the digital operator display unit selection (o1-03). When o1-03 = 0, the value is set in Hertz. When o1-03 = 4 or

5, the value is displayed in m/s. When o1-03 = 6, the value is displayed in ft/min.

<40> When checking the values of U1-03, U2-05 and U4-13 with the digital operator they are displayed in units of amperes, but when they are

checked using MEMOBUS communications, the monitor value in MEMOBUS communications is: displayed numeric value / 8192

× drive’s

rated current (A), from the condition “8192 (maximum value) = drive’s rated current (A)”.

Current Fault

Displays the current fault.

No signal output
available

U2-02

Previous Fault

Displays the previous fault.

No signal output
available

U2-03

Speed Reference at
Previous Fault

Displays the speed reference at the previous fault.

No signal output
available

0.01%

<29>

U2-04

Output Speed at
Previous Fault

Displays the output speed at the previous fault.

No signal output
available

0.01%

<29>

U2-05

Output Current at
Previous Fault

Displays the output current at the previous fault.

No signal output
available

<10> <40>

U2-06

Motor Speed at
Previous Fault

Displays the motor speed at the previous fault.

No signal output
available

0.01%

<29>

U2-07

Output Voltage at
Previous Fault

Displays the output voltage at the previous fault.

No signal output
available

0.1 Vac

U2-08

DC Bus Voltage at
Previous Fault

Displays the DC bus voltage at the previous fault.

No signal output
available

1 Vdc

U2-09

Output Power at
Previous Fault

Displays the output power at the previous fault.

No signal output
available

0.1 kW

U2-10

Torque Reference at
Previous Fault

Displays the torque reference at the previous fault.

No signal output
available

0.1%

U2-11

Input Terminal Status at
Previous Fault

Displays the input terminal status at the previous fault. Displayed as in U1-10.

No signal output
available

U2-12

Output Terminal Status
at Previous Fault

Displays the output status at the previous fault. Displayed as in U1-11.

No signal output
available

U2-13

Drive Operation Status
at Previous Fault

Displays the operation status of the drive at the previous fault. Displayed as in
U1-12.

No signal output
available

U2-14

Cumulative Operation
Time at Previous Fault

Displays the cumulative operation time at the previous fault.

No signal output
available

1 h

U2-15

Soft Starter Output at
Previous Fault

Displays the run speed after a soft start when a previous fault occurred. Displayed
as in U1-16.

No signal output
available

0.01%

<29>

U2-16

Motor q-Axis Current at
Previous Fault

Displays the q-axis current for the motor at the previous fault. Displayed as in U6-
01.

No signal output
available

0.1%

U2-17

Motor d-Axis Current at
Previous Fault

Displays the d-axis current for the motor at the previous fault. Displayed as in U6-
02.

No signal output
available

0.1%

U2-20

Heatsink Temperature
at Previous Fault

Displays the temperature of the heatsink when the most recent fault occurred.
Displayed as in U4-08.

No signal output
available

1

°C

U2-21

Peak Hold Current
during Fault

Displays the peak current that occurred just prior to the previous fault.

No signal output
available

0.01 A

U2-22

Peak Hold Frequency
during Fault

Displays the output frequency when the peak current displayed in U2-21
occurred.

No signal output
available

0.01 Hz