Connect to a pc, Y e a, 3 electrical installation – Yaskawa CIMR-LU Drives User Manual

Page 54

Advertising
background image

3 Electrical Installation

54

YASKAWA ELECTRIC TOEP C710616 38F YASKAWA AC Drive L1000A Quick Start Guide

Sinking/Sourcing Mode Selection for Safe Disable Inputs

Use jumper S3 on the terminal board to select between Sink mode, Source mode or external power supply for the Safe
Disable inputs H1 and H2 as shown in

Table 20

(Default: Sink mode, internal power supply).

Table 20 Safe Disable Input Sink / Source / External Power Supply Selection

Connect to a PC

This drive is equipped with a USB port (type-B).

The drive can connect to a USB port on a PC using a USB 2.0, AB-type cable (sold separately). After connecting the
drive to a PC, Yaskawa DriveWizard Plus software can be used to monitor drive performance and manage parameter
settings. Contact Yaskawa for more information on DriveWizard Plus.

Download and install the USB driver before connecting L1000A to a PC with the USB cable.
To obtain the driver and software of USB Copy Unit, CopyUnitManager and DriveWizardPlus, access these sites:
U.S.A: http://www.yaskawa.com

Other areas: contact a Yaskawa representative.

Figure 31

Figure 31 Connecting to a PC (USB)

Drive Internal Power Supply

External 24 Vdc Power Supply

Sinking Mode

Sourcing Mode

24 Vdc

H1

H2

HC

Jumper S3

24 Vdc

H1

H2

HC

External

24 Vdc

Jumper S3

24 Vdc

H1

H2

HC

Jumper S3

24 Vdc

H1

H2

HC

External

24 Vdc

Jumper S3

PC

(Type-B)

(Type-A)

USB Cable

(Type-AB)

Y E A

TOEP_C710616_38F_5_0.book 54 ページ 2013年12月4日 水曜日 午前9時56分

Advertising