Three-phase 600 v class drives, Table 57, A specifications – Yaskawa CIMR-LU Drives User Manual

Page 161

Advertising
background image

A Specifications

YASKAWA ELECTRIC TOEP C710616 38F YASKAWA AC Drive L1000A Quick Start Guide

161

S

p

ec

ifi

c

at

ions

A

Three-Phase 600 V Class Drives

Table 57 Power Ratings (Three-Phase 600 V Class)

<4> Rated motor capacity is calculated with a rated output voltage of 440 V.

<5> Carrier frequency can be set up to 8 kHz while keeping this current rating. Higher carrier frequency settings require derating.

<6> Carrier frequency can be set up to 5 kHz while keeping this current rating. Higher carrier frequency settings require derating.

<7> Carrier frequency can be set up to 2 kHz while keeping this current derating. Higher carrier frequency settings require derating.

Item

<1> The motor capacity (HP) refers to a NEC rated 4-pole motor. The rated output current of the drive output amps should be equal to or greater than

the motor current. Select the appropriate capacity drive if operating the motor continuously above motor nameplate current.

<2> Assumes operation at the rated output current. Input current rating varies depending on the power supply transformer, input reactor, wiring

connections, and power supply impedance.

<3> Rated motor capacity is calculated with a rated output voltage of 575 V.

<4> Carrier frequency can be set up to 3 kHz while keeping this current derating. Higher carrier frequency settings require derating.

<5> Carrier frequency can be set up to 8 kHz while keeping this current derating. Higher carrier frequency settings require derating.

<6> Carrier frequency can be set up to 5 kHz while keeping this current derating. Higher carrier frequency settings require derating.

Specification

CIMR-LU5A

0003 0004 0006 0010 0013 0017 0022 0027 0032 0041 0052 0062 0077 0099 0130 0172 0200

Maximum Applicable

Motor Capacity

(HP)

<1>

2

3

5

7.5

10

15

20

25

25-30

40

50-60 50-60

75

100

125

150

250

Input

Input

Current

(A)

<2>

3.6

5.1

8.3

12

16

23

31

38

33

44

54

66

80

108

129

158

228

Rated

Voltage

Rated

Frequency

Three-phase 500 to 600 Vac 50/60 Hz

Allowable

Voltage

Fluctuation

-10 (-15) to 10%

Allowable

Frequency

Fluctuation

±5%

Input Power

(kVA)

4.1

5.8

9.5

14

18

26

35

43

38

50

62

75

91

123

147

181

261

Output

Rated

Output

Capacity
(kVA)

<3>

3.5

<5>

4.1

<5>

6.3

<5>

9.8

<5>

12

<5>

17

<5>

22

<5>

27

<5>

32

<5>

41

<5>

52

<5>

62

<5>

77

<6>

99

<4>

129

<4>

171

<4>

199

<4>

Rated

Output

Current (A)

3.5

<5>

4.1

<5>

6.3

<5>

9.8

<5>

12.5

<5>

17

<5>

22

<5>

27

<5>

32

<5>

41

<5>

52

<5>

62

<5>

77

<6>

99

<4>

130

<4>

172

<4>

200

<4>

Overload

Tolerance

150% of rated output current for 60 s

Carrier

Frequency

User adjustable between

2 and 15 kHz

User adjustable between

2 and 10 kHz

User

adjust-

able

between

2 and 8

kHz

User adjustable between

2 and 3 kHz

Maximum

Output

Voltage (V)

Three-phase 500 to 600 Vac (proportional to input voltage)

Maximum

Output

Speed (Hz)

200 Hz (user-adjustable)

TOEP_C710616_38F_5_0.book 161 ページ 2013年12月4日 水曜日 午前9時56分

Advertising