Yaskawa CIMR-LU Drives User Manual

Page 163

Advertising
background image

A Specifications

YASKAWA ELECTRIC TOEP C710616 38F YASKAWA AC Drive L1000A Quick Start Guide

163

S

p

ec

ifi

c

at

ions

A

Protection

Functions

Motor Protection

Electronic thermal overload relay

Momentary Overcurrent

Protection

Drive stops when output current exceeds 200% of rated output current

Overload Protection

Drive stops after 60 s at 150% of rated output current

<3>

Overvoltage Protection

200 V class: Stops when DC bus voltage exceeds approx. 410 V
400 V class: Stops when DC bus voltage exceeds approx. 820 V
600 V class: Stops when DC bus voltage exceeds approx. 1040 V

Undervoltage Protection

200 V class: Stops when DC bus voltage falls below approx. 190 V
400 V class: Stops when DC bus voltage falls below approx. 380 V
600 V class: Stops when DC bus voltage falls below approx. 500 V

Heatsink Overheat Protection Thermistor

Stall Prevention

Stall Prevention is available during acceleration, and during run.

Ground Protection

Electronic circuit protection

<4>

DC Bus Charge LED

Remains lit until DC bus voltage falls below 50 V

Environment

Area of Use

Indoors

Ambient Temperature

IP00 enclosure with top protective cover: [-10 to 40°C (14 to 104°F)]
IP00 enclosure: [-10 to 50°C (14 to 122

°F)]

Humidity

95 RH% or less (no condensation)

Storage Temperature

[-20 to 60°C (-4 to 140

°F)] (short-term temperature during transportation)

Altitude

Up to 1000 meters (3280 ft.) without derating, up to 3000 meters (9842 ft.) with output current and
voltage derating

Vibration/Shock

10 to 20 Hz: 9.8 m/s

2

20 to 55 Hz: 5.9 m/s

2

(CIMR-LU2A0008 to 2A0180, 4A0005 to 4A0150, and 5A0003 to 5A0077)

or 2.0 m/s

2

(CIMR-LU2A0215 to 2A0415, 4A0180 to 4A0260, and 5A0099 to 5A0200)

Standards

• UL Underwriters Laboratories Inc:

UL508C Power Conversion Equipment

• IEC/EN 61800-3, IEC/EN 61800-5-1
• ISO International Organization for Standardization:

ISO/EN 13849-1 Cat. 3 PLd Safety of machinery - Safety-related parts of control systems

• IEC International Electrotechnical Commission:

IEC/EN 61508 SIL2 Functional safety of electrical/electronic/programmable electronic safety-
related systems safety integrity level 2

• CSA Canadian Standards Association International

<5>

:

2411-02 Elevator Equipment - Enclosed Elevator-and Escalator Electrical Equipment
3211-06 Industrial Control Equipment - Motor Controllers - Miscellaneous
C22.2 No.04-04 Bonding and Grounding of Electrical Equipment
C22.2 No.14-05 Industrial Control Equipment
B44.1/ASME-A17.5-2004 Safety Code for Elevators and Escalator Electrical Equipment used by
CSA to evaluate the L1000 to Class 2411 (Elevator Equipment)

• ANSI/ASME American Society of Mechanical Engineers/American National Standards Institute:

ANSI/ASME A17.1-2007/B44-04 Safety Code for Elevators and Escalators, Dumbwaiters,
Moving Walks, Material Lifts, and Dumbwaiters with Automatic Transfer Devices using IEC/EN
12016:2004 immunity requirements.
ANSI/ASME-A17.5-2004/CSA B44.1 - Elevator and Escalator Electrical Equipment, used by
CSA to evaluate the L1000 to Class 2411 (Elevator Equipment)

Protection Design

IP00 enclosure with top protective cover, IP00

<1> The accuracy of these values depends on motor characteristics, ambient conditions, and drive settings. Specifications may vary with different

motors and with changing motor temperature. Contact Yaskawa for consultation.

<2> For drives with B or earlier as the design revision order, 50 Hz is required. The design revision order and software version are printed on the

nameplate affixed to the side of the drive.

Refer to Model Number on page 16

for details.

<3> Overload protection may be triggered when operating with 150% of the rated output current if the output speed is less than 6 Hz.

<4> Ground protection cannot be provided when the impedance of the ground fault path is too low, or when the drive is powered up while a ground

fault is present at the output.

<5> Terminals H1, H2, DM+, and DM- on 600 V class models are designed to the functionality, but are not certified to IEC/EN 61800-5-1, ISO/EN

13849 Cat. 3, IEC/EN 61508 SIL2, Insulation coordination: class 1.

Item

Specification

TOEP_C710616_38F_5_0.book 163 ページ 2013年12月4日 水曜日 午前9時56分