B Parameter Table

YASKAWA ELECTRIC TOEP C710616 38F YASKAWA AC Drive L1000A Quick Start Guide

175

Par

ame

te

r Ta

ble

B

E2: Motor Parameters

No.

Name

Description

Setting

E2-01

<4> Default setting value varies by the drive model (o2-04).

<10> The display resolution depends on the rated output power of the drive. Models CIMR-LU2A0008 to 2A0033, 4A0005 to 4A0018, and 5A0003

to 5A0013 display values in 0.01 A units, while models CIMR-LU2A0047 to 2A0415, 4A0024 to 4A0605, and 5A0017 to 5A0200 display

values in 0.1 A units.

Motor Rated Current

Sets the motor nameplate full load current in Amps. Automatically set during
Auto-Tuning.

Default:

<4>

Min: 10% of drive
rated current
Max: 200% of
drive rated
current

<10>

E2-02

Motor Rated Slip

Sets the motor rated slip. Automatically set during Auto-Tuning.

Default:

<4>

Min: 0.00 Hz
Max: 20.00 Hz

E2-03

Motor No-Load Current

Sets the no-load current for the motor. Automatically set during Auto-Tuning.

Default:

<4>

Min: 0 A
Max: E2-01

<10>

E2-04

Number of Motor Poles

Sets the number of motor poles. Automatically set during Auto-Tuning.

Default: 4
Min: 2
Max: 48

E2-05

Motor Line-to-Line
Resistance

Sets the phase-to-phase motor resistance. Automatically set during Auto-Tuning.

Default:

<4>

Min: 0.000

Ω

Max: 65.000

Ω

E2-06

Motor Leakage Inductance

Sets the voltage drop due to motor leakage inductance as a percentage of motor rated
voltage. Automatically set during Auto-Tuning.

Default:

<4>

Min: 0.0%
Max: 40.0%

E2-07

Motor Iron-Core
Saturation Coefficient 1

Sets the motor iron saturation coefficient at 50% of magnetic flux. Automatically set
during Auto-Tuning.

Default: 0.50
Min: 0.00
Max: 0.50

E2-08

Motor Iron-Core
Saturation Coefficient 2

Sets the motor iron saturation coefficient at 75% of magnetic flux. Automatically set
during Auto-Tuning.

Default: 0.75
Min: E2-07
Max: 0.75

E2-09

Motor Mechanical Loss

Sets the motor mechanical loss as a percentage of motor rated power (kW).

Default: 0.0%
Min: 0.0%
Max: 10.0%

E2-10

Motor Iron Loss for Torque
Compensation

Sets the motor iron loss.

Default:

<4>

Min: 0 W
Max: 65535 W

E2-11

Motor Rated Power

Sets the motor rated power in kilowatts (1 HP = 0.746 kW). Automatically set during
Auto-Tuning.

Default:

<4>

Min: 0.00 kW
Max: 650.00 kW

TOEP_C710616_38F_5_0.book 175 ページ 2013年12月4日 水曜日 午前9時56分