Yaskawa CIMR-LU Drives User Manual

Page 79

Advertising
background image

4 Start-Up Programming & Operation

YASKAWA ELECTRIC TOEP C710616 38F YASKAWA AC Drive L1000A Quick Start Guide

79

S

tart-U

p

Prog

rammin

g

&

Op

er

at

io

n

4

T2-14: PM Motor Induced Voltage Constant

Enter the motor induced voltage constant.

T2-16: PG Number of Pulses Per Revolution for PM Motor Tuning

Enter the number of pulses from the PG encoder per motor rotation.

T2-17: PG Encoder Z-pulse Offset

Sets the offset between the rotor magnet axis and the PG encoder zero position. If the PG encoder offset value is unknown
or if the PG encoder is replaced, perform PG Encoder Offset Auto-Tuning.

T2-18: Speed Reference for Auto-Tuning of PG-E3 Encoder Characteristics

Note: Available in drive software PRG: 7017 or later.

Sets the speed reference for execution of Auto-Tuning of PG-E3 encoder characteristics (T2-01 = 12).

T2-19: Rotation Direction for Auto-Tuning of PG-E3 Encoder Characteristics

Note: Available in drive software PRG: 7017 or later.

Sets the direction of motor rotation for execution of Auto-Tuning of PG-E3 encoder characteristics (T2-01 = 12).

Setting 0: Forward (Up)
Setting 1: Reverse (Down)

No.

Parameter Name

Setting Range

Default

T2-14

PM Motor Induced Voltage Constant

0.0 to 2000.0

Depending on T2-02

No.

Parameter Name

Setting Range

Default

T2-16

Encoder Resolution (Pulses Per Revolution)

1 to 15000 ppr

1024 ppr

No.

Parameter Name

Setting Range

Default

T2-17

PG Encoder Z-pulse Offset

-180.0 to 180.0 deg

0.0 deg

No.

Parameter Name

Setting Range

Default

T2-18

Speed Reference for Auto-Tuning of PG-E3 Encoder Characteristics

1 to 30 r/min

10 r/min

No.

Parameter Name

Setting Range

Default

T2-19

Rotation Direction for Auto-Tuning of PG-E3 Encoder Characteristic

0, 1

0

TOEP_C710616_38F_5_0.book 79 ページ 2013年12月4日 水曜日 午前9時56分

Advertising