C: tuning, C1: acceleration and deceleration ramps – Yaskawa CIMR-LU Drives User Manual

Page 168

Advertising
background image

B Parameter Table

168

YASKAWA ELECTRIC TOEP C710616 38F YASKAWA AC Drive L1000A Quick Start Guide

C: Tuning

C parameters are used to adjust the acceleration and deceleration ramps, jerk settings, slip compensation, torque
compensation, and carrier frequency selections.

C1: Acceleration and Deceleration Ramps

No.

Name

Description

Setting

C1-01

<6> Setting ranges and defaults vary by the setting units determined by parameter o1-03.

Refer to

Defaults and Setting Ranges by Display Unit Selection (o1-03) on page 214

.

<8> Setting range value is dependent on parameter C1-10, Accel/Decel Setting Resolution. When C1-10 = 0 (units of 0.01 seconds), the setting

range becomes 0.00 to 600.00 seconds.

Acceleration Ramp 1

Sets the ramp to accelerate from 0 to maximum speed.

Default:
1.50 s

<6> <8>

Min: 0.00 s
Max:
600.00 s

<6> <8>

C1-02

Deceleration Ramp 1

Sets the ramp to decelerate from maximum speed to 0.

C1-03

Acceleration Ramp 2

Sets the ramp to accelerate from 0 to maximum speed.

C1-04

Deceleration Ramp 2

Sets the ramp to decelerate from maximum speed to 0.

C1-05

Acceleration Ramp 3
(Motor 2 Accel Time 1)

Sets the ramp to accelerate from 0 to maximum speed.

C1-06

Deceleration Ramp 3
(Motor 2 Decel Time 1)

Sets the ramp to decelerate from maximum speed to 0.

C1-07

Acceleration Ramp 4
(Motor 2 Accel Time 2)

Sets the ramp to accelerate from 0 to maximum speed.

C1-08

Deceleration Ramp 4
(Motor 2 Decel Time 2)

Sets the ramp to decelerate from maximum speed to 0.

C1-09

Fast Stop Ramp

Sets the ramp for the Fast Stop function.

C1-10

Accel/Decel Setting
Resolution

0: 0.01 s unit
1: 0.1 s unit

Default: 0
Min: 0
Max: 1

C1-11

Accel/Decel Switching
Speed

Sets the speed to switch between accel/decel ramp settings.

Default: 0.0%
Min: 0.0%
Max: 100.0%

C1-12

Motor 2 Acceleration Time

Sets the acceleration time for motor 2.
Note: Parameter C1-12 determines the acceleration time for motor 2 as long as d1-27
is not set to 0.00 Hz.

Default: 1.0 s
Min: 0.0 s
Max: 600.0 s

C1-13

Motor 2 Acceleration Time Sets the deceleration time for motor 2.

Default: 1.0 s
Min: 0.0 s
Max: 600.0 s

C1-15

Inspection Deceleration
Ramp

Sets the deceleration ramp used for inspection run.

Default: 0.00 s

<6> <8>

Min: 0.00 s
Max: 2.00 s

<6> <8>

TOEP_C710616_38F_5_0.book 168 ページ 2013年12月4日 水曜日 午前9時56分

Advertising