S: elevator parameters – Yaskawa CIMR-LU Drives User Manual

Page 91

Advertising
background image

4 Start-Up Programming & Operation

YASKAWA ELECTRIC TOEP C710616 38F YASKAWA AC Drive L1000A Quick Start Guide

91

S

tart-U

p

Prog

rammin

g

&

Op

er

at

io

n

4

S: Elevator Parameters

This section describes various functions and faults needed to operate an elevator application: braking sequence, slip
compensation, optimal adjustments at start and stop, Rescue Operation, and elevator-related faults.

S1-01: Zero Speed Level at Stop

Determines the speed to begin applying DC Injection (or Position Lock) when the drive is ramping to stop (b1-03 = 0).
Set as a percentage of the maximum output frequency (E1-04).

The function set by S1-01 changes depending on the control mode:

• V/f Control or OLV Control (A1-02 = 0, 2)

For these control modes, parameter S1-01 sets the starting speed for DC Injection Braking at stop. Once the output
speed falls below the setting of S1-01, the amount of DC Injection Braking current set in S1-03 is injected into the
motor for the time set in parameter S1-05.

• CLV Control or CLV/PM Control (A1-02 = 3, 7)

For these control modes, parameter S1-01 sets the starting speed for Position Lock at stop. Once the motor speed falls
below the setting of S1-01, Position Lock is enabled for the time set in parameter S1-05.

S1-02: DC Injection Current at Start

Determines the amount of current to use for DC Injection at start. Set as a percentage of the drive rated current.

S1-03: DC Injection Current at Stop

Determines the amount of current to use for DC Injection at stop. Set as a percentage of the drive rated current. When
using OLV Control, the DC injection current is determined by multiplying S1-03 by S3-25 or S3-26.

S1-04: DC Injection / Position Lock Time at Start

Determines how long the drive should perform DC Injection at start. In CLV and CLV/PM, S1-04 determines how long
Position Lock should be performed. During this time, the drive allows motor flux to develop, which is essential for
applying torque quickly once the brake is released. A setting of 0.00 disables S1-04.

S1-05: DC Injection / Position Lock Time at Stop

Determines how long the drive should perform DC Injection at stop. In CLV and CLV/PM, S1-05 determines how long
Position Lock should be performed. A setting of 0.00 disables S1-05.

No.

Parameter Name

Setting Range

Default

S1-01

Zero Speed Level at Stop

0.000 to 9.999%

Determined by A1-02

No.

Parameter Name

Setting Range

Default

S1-02

DC Injection Current at Start

0 to 100%

50%

No.

Parameter Name

Setting Range

Default

S1-03

DC Injection Current at Stop

0 to 100%

50%

No.

Parameter Name

Setting Range

Default

S1-04

DC Injection / Position Lock Time at Start

0.00 to 10.00 s

0.40 s

No.

Parameter Name

Setting Range

Default

S1-05

DC Injection / Position Lock Time at Stop

0.00 to 10.00 s

0.60 s

TOEP_C710616_38F_5_0.book 91 ページ 2013年12月4日 水曜日 午前9時56分

Advertising