4 start-up programming & operation – Yaskawa CIMR-LU Drives User Manual

Page 126

Advertising
background image

4 Start-Up Programming & Operation

126

YASKAWA ELECTRIC TOEP C710616 38F YASKAWA AC Drive L1000A Quick Start Guide

• When the lightest load direction is up, the drive stops after Light Load Direction Search and then accelerates upwards to

the Rescue Operation speed set in parameter S4-15. The output terminals set for “Light Load Direction” (H2-

= 54)

and “Light Load Direction detection status”(H2-

= 55) will close.

Figure 70

Figure 77 Light Load Direction Detection (Up)

• When the lightest direction is down, then after Light Load Direction Detection is finished the drive immediately

accelerates to the Rescue Operation speed set in S4-15 without stopping. An output terminal set for “Light load
direction” (H2-

= 54) will stay open, and an output terminal set for “Light Load Direction detection status”(H2-

= 55) will close.

Figure 71

Figure 78 Light Load Direction Detection (Down)

H1-

غغ = 55

(Rescue Operation)

Up

Off (open)

Off (open)

Up

Down

Speed agree torque calculations

Elevator moves in the
direction of the light load

Up/Down command

Up command (internal)

Down command (internal)

On (closed)

On (closed)

㧔Light Load Direction Search status㧕

H2-

= 55

㧔Light load direction㧕

H2-

= 54

Off (open)

Off (open)

On (closed)

On (closed)

H1-

غغ = 55

(Rescue Operation)

Up

Off (open)

Off (open)

Down

Speed agree torque calculations

Elevator moves in the
direction of the light load

Up/Down command

Up command (internal)

Down command (internal)

On (closed)

On (closed)

㧔Light Load Direction Search status㧕

H2-

= 55

㧔Light load direction㧕

H2-

= 54

Off (open)

Off (open)

On (closed)

TOEP_C710616_38F_5_0.book 126 ページ 2013年12月4日 水曜日 午前9時56分