Table 26 Auto-Tuning Input Data

Properly set the motor and PG encoder data before performing PG Encoder Offset Tuning.

Table 27 Types of Auto-Tuning for PG Encoder Offset

Input Value

<1> Available in drive software versions PRG: 7017 or later.

<2> Depends on T2-13 setting.

Input

Param-

eter

Unit

Tuning Type (T2-01)

0

Motor

Param-

eter

Settings

1

Station-

ary

2

Station-

ary

Stator

Resist-

ance

3

Initial

Magnet

Pole

Search

Param-

eters

Auto-

Tuning

4

Encoder

Offset

Station-

ary Auto-

Tuning

10

Encoder

offset

rotation-

al Auto-

Tuning

11

Back

EMF

Constant

12

Auto-

Tuning of

PG-E3

Encoder

Charac-

teristics

Control Mode

A1-02

7

7

7

7

7

7

7

7

Motor Rated Power

T2-04

kW

Yes

Yes

N/A

N/A

N/A

N/A

N/A

N/A

Motor Rated Voltage

T2-05

V

Yes

Yes

N/A

N/A

N/A

N/A

N/A

N/A

Motor Rated Current

T2-06

A

Yes

Yes

Yes

N/A

N/A

N/A

N/A

N/A

Number of Motor Poles

T2-08

N/A

Yes

Yes

N/A

N/A

N/A

N/A

N/A

N/A

Motor Rated Speed

T2-09

r/min

Yes

Yes

N/A

N/A

N/A

N/A

N/A

N/A

Stator 1 Phase Resistance

T2-10

Ω

Yes

N/A

N/A

N/A

N/A

N/A

N/A

N/A

d-Axis Inductance

T2-11

mH

Yes

N/A

N/A

N/A

N/A

N/A

N/A

N/A

q-Axis Inductance

T2-12

mH

Yes

N/A

N/A

N/A

N/A

N/A

N/A

N/A

Induced Voltage Constant
Unit Selection

T2-13

N/A

Yes

N/A

N/A

N/A

N/A

N/A

N/A

N/A

Voltage Constant

T2-14

<2>

Yes

N/A

N/A

N/A

N/A

N/A

N/A

N/A

PG Number of Pulses per
Revolution

T2-16

N/A

Yes

Yes

N/A

N/A

N/A

N/A

N/A

N/A

Z Pulse Offset

T2-17

deg

(mech.)

Yes

N/A

N/A

N/A

N/A

N/A

N/A

N/A

Speed Reference for
Auto-Tuning of PG-E3
Encoder Characteristics

<1>

T2-18

r/min

N/A

N/A

N/A

N/A

N/A

N/A

N/A

Yes

Rotation Direction for
Auto-Tuning of PG-E3
Encoder Characteristics

<1>

T2-19

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

Yes

Type

Setting

Requirements and Benefits

Initial Magnet Pole Search

Parameters Auto-Tuning

T2-01 = 3

• Should be performed after motor Auto-Tuning in order to determine the PG encoder tuning method.
• Attempts to detect the motor rotor position, determines whether PG encoder offset can be tuned using

Stationary Encoder Offset Tuning and sets parameters needed for Initial Magnet Pole Search (n8-36,
n8-37).

• When using the Rescue Operation mode, perform this tuning to let the drive automatically set the

parameters needed for Initial Magnet Pole Search with power supply from a battery or UPS (n8-81,
n8-82).

• Must be performed when using an incremental PG encoder.

Important: If this tuning fails when using a PG-X3 card with an incremental PG encoder the motor
cannot be driven using an incremental PG encoder. Change the PG encoder to an absolute PG encoder.

Stationary PG Encoder

Offset

Auto-Tuning

T2-01 = 4

• Tunes the PG encoder offset without rotating the motor.
• If the PG encoder offset cannot be tuned properly by this method, try Rotating PG Encoder Offset

Tuning.

Rotational PG Encoder

Offset

Auto-Tuning

T2-01 = 10

• Tunes the PG encoder offset while rotating the motor.
• Motor and mechanical system must be uncoupled (ropes must be removed from traction sheave).