B Parameter Table

YASKAWA ELECTRIC TOEP C710616 38F YASKAWA AC Drive L1000A Quick Start Guide

205

Par

ame

te

r Ta

ble

B

T2: PM Motor Auto-Tuning

No.

Name

Description

Setting

T2-01

Motor Auto-Tuning Mode
Selection

0: Motor Data input
1: Stationary Auto-Tuning
2: Stationary stator resistance Auto-Tuning
3: Initial magnet pole search parameters Auto-Tuning
4: Encoder offset stationary Auto-Tuning
10: Encoder offset rotational Auto-Tuning
11: Rotational back EMF constant Auto-Tuning
12: Auto-Tuning of PG-E3 encoder characteristics
Setting 12 is available in drive software versions PRG: 7017 or later.
Auto-Tuning of PG-E3 encoder characteristics requires a PG-E3 option with software
version 1102 or later. To identify the PG-E3 software version, refer to the PG-E3
labeling on the option, in the field designated “C/N” (S + four digit number).

Default: 0
Min: 0
Max: 12

T2-04

Motor Rated Power

Sets the motor rated power as indicated on the motor nameplate.

Default:

<4>

Min: 0.00 kW
Max: 650.00 kW

T2-05

Motor Rated Voltage

Enter the motor rated voltage as indicated on the motor nameplate.

Default:
200.0 V

<9>

Min: 0.0 V
Max: 255.0 V

<9>

T2-06

Motor Rated Current

Enter the motor rated current as indicated on the motor nameplate.

Default:

<4>

Min: 10% of drive
rated current
Max: 200% of
drive rated
current

<10>

T2-08

Number of Motor Poles

Enter the number of motor poles for the motor as indicated on the motor nameplate.

Default: 6
Min: 2
Max: 120

<43>

T2-09

Motor Base Speed

Enter the base speed for the motor as indicated on the motor nameplate.

Default: 150 r/min
Min: 0 r/min
Max: 24000 r/min

T2-10

Single Phase Stator
Resistance

Enter the 1-phase resistance of the stator winding.

Default: –
Min: 0.000

Ω

Max: 65.000

Ω

T2-11

Motor d-Axis Inductance

Enter the d-axis inductance for the motor as indicated on the motor nameplate.

Default: –
Min: 0.00 mH
Max: 600.00 mH

T2-12

Motor q-Axis Inductance

Enter the q-axis inductance for the motor as indicated on the motor nameplate.

Default: –
Min: 0.00 mH
Max: 600.00 mH

T2-13

Induced Voltage Constant
Unit Selection

0: mV/(r/min). E5-09 will automatically be set to 0.0, and E5-24 will be used.
1: mV/(rad/sec). E5-24 will automatically be set to 0.0, and E5-09 will be used.

Default: 1
Min: 0
Max: 1

T2-14

Motor Induced Voltage
Constant

Enter the induced voltage coefficient for the motor as indicated on the motor
nameplate.

Default: –
Min: 0.0
Max: 6500.0

<30>

T2-16

Encoder Resolution

Sets the number of pulses per revolution for the PG being used (pulse generator or
encoder).

Default: 1024 ppr
Min: 1 ppr
Max: 15000 ppr

T2-17

Encoder Offset

Sets the offset between encoder offset and the rotor magnetic axis.

Default: 0.0 deg
Min: -180.0 deg
Max: 180.0 deg

T2-18

<44>

Speed Reference for Auto-
Tuning of PG-E3 Encoder
Characteristics

Sets the speed reference for execution of Auto-Tuning of PG-E3 encoder
characteristics (T2-01 = 12).

Default: 10 r/min
Min: 1 r/min
Max: 30 r/min

TOEP_C710616_38F_5_0.book 205 ページ 2013年12月5日 木曜日 午前11時22分