B Parameter Table

YASKAWA ELECTRIC TOEP C710616 38F YASKAWA AC Drive L1000A Quick Start Guide

169

Par

ame

te

r Ta

ble

B

C2: Jerk Settings

C3: Slip Compensation

No.

Name

Description

Setting

C2-01

<6> Setting ranges and defaults vary by the setting units determined by parameter o1-03.

Refer to

Defaults and Setting Ranges by Display Unit Selection (o1-03) on page 214

.

Jerk at Accel Start

Five different jerk values can be set. They are automatically applied as shown in the
figure below.

Default: 0.50 s

<6>

Min: 0.00 s
Max: 10.00 s

<6>

C2-02

Jerk at Accel End

Default: 0.50 s

<6>

Min: 0.00 s
Max: 10.00 s

<6>

C2-03

Jerk at Decel Start

Default: 0.50 s

<6>

Min: 0.00 s
Max: 10.00 s

<6>

C2-04

Jerk at Decel End

Default: 0.50 s

<6>

Min: 0.00 s
Max: 10.00 s

<6>

C2-05

Jerk below Leveling Speed Sets the jerk used when the speed reference is lower than the leveling speed setting.

Default: 0.50 s

<6>

Min: 0.00 s
Max: 10.00 s

<6>

No.

Name

Description

Setting

C3-01

<5> Default setting is determined by the control mode (A1-02).

Slip Compensation Gain

Sets the gain for the motor slip compensation function.

Default: 1.0
Min: 0.0
Max: 2.5

C3-02

Slip Compensation
Primary Delay Time

Adjusts the slip compensation function delay time.

Default: 2000 ms
Min: 0 ms
Max: 10000 ms

C3-03

Slip Compensation Limit

Sets an upper limit for the slip compensation function as a percentage of motor rated
slip for motor 1 (E2-02).

Default: 200%
Min: 0%
Max: 250%

C3-04

Slip Compensation
Selection during
Regeneration

0: Disabled.
1: Enabled above 6 Hz.
2: Enabled whenever slip compensation is possible.

Default: 0
Min: 0
Max: 2

C3-05

Output Voltage Limit
Operation Selection

0: Disabled.
1: Enabled. Automatically decreases motor flux when output voltage saturation is
reached.
Note: Available control modes for parameter C3-05 vary by drive model: Models
CIMR-LU2A0008 to 2A0415, 4A0005 to 4A0605, and 5A0003 to 5A0200: Available
when A1-02 = 2, 3

Default:

<5>

Min: 0
Max: 1

Time

C2-01

C2-05

C2-05

C2-04

C2-02

C2-03

ON

Up/Down command

Output speed

OFF