Speed selection using digital inputs (b1-01 = 0) – Yaskawa CIMR-LU Drives User Manual

Page 81

Advertising
background image

4 Start-Up Programming & Operation

YASKAWA ELECTRIC TOEP C710616 38F YASKAWA AC Drive L1000A Quick Start Guide

81

S

tart-U

p

Prog

rammin

g

&

Op

er

at

io

n

4

Travel Stop

The drive stops under the following conditions:

• The Up or Down command is removed.
• d1-18 is set to 1 or 2 and the Up/Down or Leveling Speed signal (H1-

= 53) is removed.

• d1-18 is set to 3 and all speed inputs are removed.
• A fault occurs. The stopping method depends on the specific fault that occurred, in combination with certain parameter

settings.

• The Safe Disable inputs are opened or a Base Block signal is input. In this case, the brake is applied immediately and

the drive output shuts off.

Speed Selection Using Digital Inputs (b1-01 = 0)

Set parameter b1-01 = 0 to enable the speed selection using the drive digital inputs. Use parameter d1-18 to determine
different travel speeds selected by the digital inputs.

NOTICE: Always turn off the RUN command before changing the setting of parameters d1-18 (Speed Reference Selection Mode), b1-

01 (Speed Reference Selection), or H1-

(Multi-Function Digital Inputs). If the RUN command is on when changing any of these

settings, the motor may unexpectedly start running, and could result in injury.

Multi-Speed Inputs 1, 2 (d1-18 = 0 or 3)
Speed Selection

When d1-18 = 0 or 3, multi-function digital inputs are preset as shown below.

Different speed reference settings can be selected by combining the three digital inputs as shown in the table below.

Note: Parameters d1-19 through d1-26 are displayed only if d1-18 is set to 1 or 2.

d1-18

Speed Selection

0 (default)

Multi-speed inputs 1, Speed references are set in d1-01 to d1-08

1

Separate speed inputs, Speed references are set in d1-19 to d1-24 and d1-26, Higher speed has priority

2

Separate speed inputs, Speed references are set in d1-19 to d1-24 and d1-26, Leveling speed has priority

3

Multi speed inputs 2, Speed references are set in d1-02 to d1-08, Stop if no speed selection input is enabled

Terminal

Parameter Number

Set Value

Details

S5

H1-05

3

Multi-Speed Reference 1

S6

H1-06

4

Multi-Speed Reference 2

S7

H1-07

5

Multi-Speed Reference 3

Digital Inputs

0 = Off, 1 = On

Selected Speed

Multi-Speed

Reference 1

Multi-Speed

Reference 2

Multi-Speed

Reference 3

d1-18 = 0

d1-18 = 3

0

0

0

Speed reference 1 (d1-01)

Stop

1

0

0

Speed reference 2

(d1-02 or terminal A1, A2 input value if H3-02 or H3-10 is set to 2)

0

1

0

Speed reference 3

(d1-03 or terminal A1, A2 input value if H3-02 or H3-10 is set to 3)

1

1

0

Speed reference 4 (d1-04)

0

0

1

Speed reference 5 (d1-05)

1

0

1

Speed reference 6 (d1-06)

0

1

1

Speed reference 7 (d1-07)

1

1

1

Speed reference 8 (d1-08)

TOEP_C710616_38F_5_0.book 81 ページ 2013年12月4日 水曜日 午前9時56分