Wiring Servo Relay Units

Section 3-4

6.

Signal Switches

Note (a) An external encoder with a line-driver output can be connected.

(b) For 4 to 20 mA current inputs, voltage input (+) and current input

do not need to be connected.

7.

Terminating Resistance Switch
Set this terminating resistance switch to ON when the Servo Relay Unit is
at the end of the RS-422A line and the PORT2 terminal is not connected
to PORT1 on another Servo Relay Unit.

8.

Servo Driver Phase B Switches
When the high-speed counter is set to absolute mode CW in the System
Setup, inputs are the inverse of the phase from the encoder output phase
B from the Servo Driver. The high-speed counter is used in incremental
mode for all other System Setup settings.

Switch

Setting details

CNT1
SER_A

SER_A

Connects the Servo #1 phase A to the Motion Control
Module's CNT1 phase A.

TER_A

Connects the external encoder phase A to the Motion
Control Module's CNT1 phase A. (See note a.)

CNT1
SER_B

SER_B

Connects the Servo #1 phase B to the Motion Control
Module's CNT1 phase B.

TER_B

Connects the external encoder phase B to the Motion
Control Module's CNT1 phase B. (See note a.)

CNT1
SER_Z

SER_Z

Connects the Servo #1 phase Z to the Motion Control
Module's CNT1 phase Z.

TER_Z

Outputs the Servo #1 phase Z output from the terminal.

DA2

Y axis

Connects FQM1-MMA21 analog output 2 to Servo #2
REF.

X axis

Connects FQM1-MMA21 analog output 2 to Servo #1
TREF.

AD

VOL

Sets analog inputs as voltage inputs.

CUR

Sets analog inputs as current inputs. (See note b.)

TER_A

SER_A

CNT1

SER_B

CNT1

TE

R_B

CUR

SER_Z

CNT1

DA2

VOL

AD

TER_Z

X axis

Y axis

TERM

ON

OFF

SW6

INC

INC

SW7

SW8

servo2

ABS_CW-

servo1

ABS_CW-

Servo #2
phase B switch

Servo #1
phase B switch