Pulse Inputs

Section 7-5

Minimum response pulse

At 50 kHz

At 500 kHz Operation may not be reliable above 50 kHz.

Item

Specification

OFF

ON

50%

OFF

ON

T1

T2

T4

T3

OFF

ON

50%

ON

50%

OFF

Encoder Inputs A and B

Waveform of Encoder Inputs A and B
Signal rise and fall must be 3

µs max.

50-kHz pulse with 50% duty ratio

20

µs min.

10

µ

s min.

10

µ

s min.

3

µs max.

3

µs max.

Relationship to Phase Differential Inputs A and B
T1, T2, T3,and T4 must be 4.5

µs min.

There must be 4.5

µs min. between phase-A and

phase-B change points.

20

µs min.

Phase A

Phase B

Encoder Input Z or Sensor Input

Encoder Input Z Waveform
The pulse width must be 90

µs min.

90

µs min.

OFF

ON

50%

OFF

ON

T1

T2

T4

T3

OFF

ON

50%

ON

50%

OFF

Encoder Inputs A and B

Encoder Inputs A and B Waveform
Square waveform
50-kHz pulse with 50% duty ratio

20

µs min.

10

µ

s min.

10

µ

s min.

Relationship to Phase Differential Inputs A and B
T1, T2, T3,and T4 must be 4.5

µs min.

There must be 4.5

µs min. between phase-A and

phase-B change points.

20

µs min.

Phase A

Phase B

Encoder Input Z or Sensor Input

Encoder Input Z Waveform
The pulse width must be 90

µs min.

90

µs min.

OFF

ON

50%

OFF

ON

T1

T2

T4

T3

OFF

ON

50%

ON

50%

OFF

Encoder Inputs A and B

Encoder Inputs A and B Waveform
Square waveform
1-MHz pulse with 50% duty ratio

1

µs min.

0.5

µs min.

0.5

µs min.

Relationship with Phase Differential Inputs A and B
T1, T2, T3,and T4 must be 0.5

µs min.

There must be 0.5

µs min. between phase-A and

phase-B change points.

2

µs min.

Encoder Input Z or Sensor Input

Encoder Input Z Waveform
The pulse width must be 10

µs min.

10

µs min.

Advertising