Omron HOME SECURITY SYSTEM - MOTION SENSOR FQM1-MMA21 User Manual

Page 43

Advertising
background image

20

Function Tables Arranged by Purpose

Section 1-7

Synchronizing 3
or more axes

Make control
cycle as short
as possible with
Modules syn-
chronized

Synchronizing
Motion Control
Modules only

Sync Mode,
Sync Cycle
Time

5-1 Synchronous Operation between Modules

Set Sync Mode to Sync and Sync Cycle Time to
between 0.1 and 10.0 ms.

If the Coordinator Module cycle varies or gets
too long after connecting the FQM1 to peripheral
devices, Motion Control Module operation can
be synchronized to have short control cycles for
Motion Control Modules only.

The Sync Cycle Time can be set to any value.

Synchronous
Data Link Bit
Area

Same as “Synchronous Data Link Bit Area,”
above.

Cycle Time
(Motion Control
Modules)

5-1 Synchronous Operation between Modules

The Coordinator Module's constant cycle time is
set as the FQM1 Sync Cycle Time (as above).
The I/O refresh interval for the Motion Control
Module in that Sync Cycle Time is made con-
stant and the I/O cycle with external interfaces is
also made constant.

Prohibit System
Interruption of
the Sync Mode

Same as “Prohibit System Interruption of the
Sync Mode” above.

Control opera-
tion using pulse
and analog data
simultaneously

Synchronizing
Motion Control
Modules to
Coordinator
Module cycle or
synchronizing
between Motion
Control Mod-
ules only

Synchronous
Data Selection

5-4 Synchronous Data Refresh

Information for I/O from different Motion Control
Modules can be stored within Modules and a
control loop created.

Select the type of synchronous data.

• Ladder execution results
• High-speed counter PV
• Pulse output PV
• Analog input values
• Analog output values
• Built-in I/O inputs

Fast control
loops

Changing to
Async Mode

Sync Mode

5-1 Synchronous Operation between Modules

Set the Sync Mode to Async.

Each Module will no longer be synchronized,
bus refreshing will stop, and the Motion Control
Module overhead time will be minimized.

The minimum overhead time for FQM1-MMP21
is 0.19 ms.

Purpose

Operation

Function used

Details

Advertising