Rs-232c port specifications – Omron HOME SECURITY SYSTEM - MOTION SENSOR FQM1-MMA21 User Manual

Page 89

Advertising
background image

66

Wiring

Section 3-2

Connection Example to Programmable Terminal (PT)

Direct Connection from RS-232C to RS-232C

• Communications Mode: NT Link (1:N, N = 1 node only)

• OMRON Cables with Connectors: XW2Z200T (2 m)

XW2Z500T (5 m)

RS-232C Port Specifications

Note

Baud rates for the RS-232C are specified only up to 19.2 kbps. The FQM1
supports serial communications from 38.4 kbps to 57.6 kbps, but some com-
puters cannot support these speeds. Lower the baud rate if necessary.

RS-232C

PT

1:N NT Link

RS-232C port

PT

Shell

1
2
3
4
5
6
7
8
9

FG

SD
RD
RS
CS

5V


SG

Coordinator Unit

Shell

1
2
3
4
5
6
7
8
9

FG
FG
SD
RD
RS
CS

5V

DR
ER
SG

RS-232C
interface

Signal

Signal

RS-232C
interface

9-pin D-sub
(male)

9-pin D-sub
(male)

Pin
No.

Pin
No.

Item

Specification

Communications method

Half duplex

Synchronization

Asynchronous

Baud rate

0.3, 0.6, 1.2, 2.4, 4.8, 9.6, 19.2, 38.4, or 57.6 kbps
(See note.)

Transmission distance

15 m max.

Interface

EIA RS-232C

Protocol

Host Link, 1:N NT Link, No-protocol, or Peripheral Bus
(Toolbus)

Advertising