7-1 specifying the startup mode, 7-2 program protection, Specifying the startup mode – Omron HOME SECURITY SYSTEM - MOTION SENSOR FQM1-MMA21 User Manual

Page 141: Program protection

Advertising
background image

118

Operation Settings at Startup and Maintenance Functions

Section 5-7

5-7

Operation Settings at Startup and Maintenance Functions

This section describes the following operation settings at startup and mainte-
nance functions.

• Operating mode at startup

• Program protection

• Remote programming and monitoring

• Flash memory

5-7-1

Specifying the Startup Mode

The operating mode when the power is turned ON can be specified in the
System Setup.

System Setup

Note

The operating mode at startup for Motion Control Modules will be the same as
that for the Coordinator Module when in Sync Mode, but will be RUN mode
when in ASync Mode.

5-7-2

Program Protection

The FQM1 provides the following kinds of protection for user programs.

Read Protection
Using Passwords

Read and display access to the user program area can be blocked from the
CX-Programmer. Protecting the program will prevent unauthorized copying of
the program and loss of intellectual property.

A password is set for program protection from the CX-Programmer and read
access is prevented to the whole program.

Note

(1) If you forget the password, the program in the FQM1 cannot be trans-

ferred to the computer.

(2) If you forget the password, programs can be transferred from the comput-

er to the FQM1. Programs can be transferred from the computer to the
FQM1 even if the password protection has not been released.

Power ON

Tab page

Name

Details

Settings

Default

Startup Startup

Mode

Specifies the
initial operating
mode when the
power is turned
ON.

System Setup disabled

• RUN mode

System Setup enabled

• PROGRAM mode
• MONITOR mode
• RUN mode

System Setup
disabled

Advertising