355

Auxiliary Area Allocations

Appendix D

A606 to
A607

00 to 15 High-

speed
Counter
2

For following
counter modes
• Absolute linear

(CW

−)

• Absolute circular
• Absolute linear

(CW+)

PV of absolute
number of rota-
tions

Same as for A604 and A605 for high-speed counter 1 except that
measuring the high-speed counter frequency is not possible for
high-speed counter 2.

For following
counter modes
• Linear counter
• Circular counter

Monitor data

A608

00

High-
speed
counter 1
status

Target Comparison In-progress Flag

OFF: Target value comparison is not being performed for
CTBL(882).
Note This flag is always OFF for range comparison.

ON: Target value comparison is being performed for CTBL(882).

Note Target comparison is continued without interruption once it
has been started (as opposed to range comparison), so this flag
can be used to check whether target comparison is in progress.

01

PV Overflow/Underflow Flag

OFF: There is no counter overflow or underflow in Linear Counter
Mode. This flag will always be OFF in Circular Counter Mode.
ON: There is a counter overflow or underflow in Linear Counter
Mode. The counter PV will be fixed at the overflow or underflow
limit. This flag will be cleared when the High-speed Counter Start
Bit is turned OFF.

03

Phase Z Input Reset Flag (ON for
one cycle)

ON for one cycle when the counter PV is reset with the counter
reset method set to a phase Z + software reset.

Note This flag will turn ON for one cycle after the counter PV is
reset if the phase Z signal (reset input) turns ON while the High-
speed Counter Reset Bit (A610.01) is ON.

04

Absolute No. of Rotations Read Error
Flag

OFF: No error
ON: Error

05

Absolute No. of Rotations Read
Completed Flag

OFF: Rotations being read or reading has not been executed.
ON: Reading has been completed (Turned ON when serial recep-
tion of the number of rotations has been completed.)

06

Measuring Flag (measurement mode
1 or 2)

Note Valid when Counter Data Dis-
play in System Setup is set to
Counter Movements (mode 1) or Fre-
quency (mode 2).

OFF: Changes in the counter PV or the counter frequency is not
being measured.
ON: Changes in the counter PV or the counter frequency is being
measured.
In measurement mode 1, this flag will turn ON at the beginning of
the sampling time after the Measurement Start Bit (A610.02) is
turned ON.

07

High-speed Counter Operating Flag

OFF: Counter is not operating.
ON: Counter is operating.

08

Count Latched Flag

OFF: Count has not been latched.
ON: Latching the count has been completed for the latch input.

12

Absolute Offset Preset Error Flag

OFF: No error occurred when saving the absolute offset.
ON: An error occurred when saving the absolute offset.

A609

00

High-
speed
counter 2
status

Target Comparison In-progress Flag

Same as for high-speed counter 1.

01

PV Overflow/Underflow Flag

03

Phase Z Input Reset Flag (ON for
one cycle)

04

Absolute No. of Rotations Read Error
Flag

05

Absolute No. of Rotations Read
Completed Flag

06

Measuring Flag (measurement mode
1 or 2)

07

High-speed Counter Operating Flag

08

Count Latched Flag

12

Absolute Offset Preset Error Flag

Address

Bits

Name

Function