1 list of models, 2 general specifications, List of models – Omron HOME SECURITY SYSTEM - MOTION SENSOR FQM1-MMA21 User Manual

Page 55: General specifications

Advertising
background image

32

List of Models

Section 2-1

2-1

List of Models

Note

If CX-Programmer Ver. 5.0 is used with the FQM1, the FQM1 Patch Software
must be installed.

2-2

General Specifications

General Specifications

Name

Type

Model

Specifications

Coordinator Mod-
ule

Standard
(with built-in I/O)

FQM1-CM001

Program capacity: 5 Ksteps
16 general-purpose inputs, 8 general-purpose outputs
Peripheral port, RS-232C port, RS-422A port

Motion Control
Modules

Pulse I/O

FQM1-MMP21

Program capacity: 5 Ksteps
2 pulse inputs, 2 pulse outputs, 12 general-purpose
inputs, 8 general-purpose outputs

Analog I/O

FQM1-MMA21

Program capacity: 5 Ksteps
2 pulse inputs, 1 analog input, 2 analog outputs,
12 general-purpose inputs, 8 general-purpose outputs

End Module

Standard

FQM1-TER01

Connects to the right end of the FQM1.

Servo Relay Units

---

XW2B-80J7-1A

Simplifies wiring from the Motion Control Module to two
Servo Drivers, wiring for all switches, sensors, and other
general-purpose I/O, and wiring the RS-422A line.

FQM1 Flexible
Motion Controller
Set

Set for pulse I/O

FQM1S-MC231

A set including the CJ1W-PA202, FQM1-CM001, FQM1-
MMP21, and FQM1-TER01

Set for analog I/O FQM1S-MC222

A set including the CJ1W-PA205R, FQM1-CM001,
FQM1-MMA21, and FQM1-TER01

Programming
Device

CX-Programmer
Ver. 5.0 or later

WS02-CXPC1-E-V5

@

(See note.)

Used for System Setup setting, programming, and moni-
toring for Coordinator Modules and Motion Control Mod-
ules. The FQM1 patch file is used with CX-Programmer
Ver. 5.0.

Item

Specifications

Insulation resistance

20 M

Ω min. (at 500 VDC) between AC external and GR terminals (See note 1.)

Dielectric strength

2,300 V AC 50/60 Hz for 1 min between AC external and GR terminals (See notes 1 and 2.)
Leakage current: 10 mA max.

720 V AC 50/60 Hz for 1 min between DC external and GR terminals (See note 1.)
Leakage current: 10 mA max.

Noise immunity

2 kV on power supply line (conforming to IEC61000-4-4)

Vibration resistance

10 to 57 Hz, 0.075-mm amplitude, 57 to 150 Hz, acceleration: 9.8 m/s

2

in X, Y, and Z direc-

tions for 80 minutes total (Time coefficient: 8 minutes

× coefficient factor 10 = total time 80

min.) (conforming to JIS C0040)

Shock resistance

147 m/s

2

3 times each in X, Y, and Z directions (conforming to JIS C0041)

Ambient operating tem-
perature

0 to 55

°C

Ambient operating
humidity

10% to 90% (with no condensation)

Atmosphere

Must be free from corrosive gases

Ambient storage temper-
ature

−20 to 75°C

Grounding

Less than 100

Enclosure

Mounted in a panel.

Dimensions

49

Ч 90 Ч 80 mm (W × H × D) (not including cables)

Weight

All models are each 5 kg max.

Safety measures

Conforms to EC directives, C-Tick, and cULus.

Advertising