Pulse Outputs

Section 7-6

7-6-5

Applicable Instructions

The following seven instructions can be used to control pulse outputs. The
relationship between the instruction and the types of pulse output that is pos-
sible is also listed in the following table.

Instructions Ineffective
during Pulse Output

Once pulse output has been started by an instruction, the output cannot
always be changed with an instruction. Refer to 7-6-15 Pulse Output Starting
Conditions
f
or details on the allowed combinations of pulse output instruc-
tions.

Instruction

Control

Positioning (Independent Mode)

Speed Control (Continuous

Mode)

No

acceleration/
deceleration,
single-phase

output

Acceleration/deceleration,

single-phase output

No

acceleration/
deceleration,
single-phase

output

Acceleration/

deceleration,
single-phase

output

No trapezoid,

acceleration

and

deceleration

Trapezoid,

separate

acceleration and

deceleration rates

PULS(886)

Sets number of out-
put pulses or abso-
lute position.

OK

OK

No

No

No

SPED(885)

Controls pulse out-
put without acceler-
ation or
deceleration (num-
ber of pulses set
with PULS(886) for
positioning).

OK

No

No

OK

No

ACC(888)

Controls pulse out-
put with same
acceleration and
deceleration with-
out trapezoid (num-
ber of pulses set
with PULS(886) for
positioning).

No

OK

No

No

OK

PULS(886)
for Elec-
tronic Cam

Sets absolute posi-
tion or frequency
and outputs pulses.

OK

No

No

No

No

PLS2(887)

Controls pulse out-
put with different
acceleration and
deceleration with
trapezoid (number
of pulses is also set
using PLS2(887)).

No

No

OK

No

No

INI(880)

Stops pulse output.

OK

OK

OK

OK

OK

PRV(881)

Reads the current
PV for pulse output.

OK

OK

OK

OK

OK